文献速递牙体牙髓病口腔颌面外科

机器人、动态与静态导航辅助根尖显微手术的精度与操作时间对比:一项体外研究

Comparison of Accuracy and Operation Time in Robotic, Dynamic, and Static-Assisted Endodontic Microsurgery: An In Vitro Study.
PubMed 文献 · J Endod · 2024-06-03

结果显示RA-EMS在平台、角度和切除角度偏差上显著优于其他两组,SN-guided操作时间最短,三种方法临床精度均可接受。

要点

  • RA-EMS在平台、角度及切除角度偏差上显著优于动态和静态导航。
  • SN-guided操作时间最短,其次为RA-EMS,DN-guided最长。
  • 三种方法均在临床可接受精度范围内,RA-EMS具潜在应用前景。

核心结论

  • 三种辅助方式均达到临床可接受的精度和操作时间,RA-EMS精度更优。
  • RA-EMS在牙髓病学中具有潜在应用前景,仍需高质量临床研究验证。

研究设计与样本

  • 随机分为RA-EMS、DN-guided EMS和SN-guided EMS三组,行截骨和根尖切除。
  • 术前规划与术后锥形束CT导入精度分析系统,基于解剖结构配准评估精度。
  • 操作时间从踩下脚踏板至车针达到目标深度记录。
  • 采用Kruskal-Wallis和Scheirer-Ray-Hare检验,显著性水平P < .05。

主要发现

  • RA-EMS在平台偏差、角度偏差和切除角度偏差上显著高于DN-guided和SN-guided(P < .05)。
  • RA-EMS在切除长度偏差上显著高于DN-guided(P < .05)。
  • 三种方法操作时间存在显著差异,SN-guided最短,RA-EMS次之,DN-guided最长。
  • DN-guided组内不同颌骨类型在角度偏差上存在差异(P < .05)。

临床怎么用

  • RA-EMS可提供更高精度,适合对精度要求高的根尖显微手术。
  • SN-guided操作时间最短,可在追求效率时优先考虑。
  • DN-guided操作时间较长,且颌骨类型可能影响角度偏差。

局限性

  • 本研究为体外模型研究,结论需进一步高质量临床研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: This study aimed to compare the accuracy and operation time (OT) of robotic-assisted endodontic microsurgery (RA-EMS), dynamic navigation-guided (DN-guided) EMS, and static navigation-guided (SN-guided) EMS. METHODS: Seventy-two teeth from three sets of standardized jaw models (TrueTooth, DELendo, Santa Barbara, CA) randomly assigned into 3 groups underwent osteotomy and root-end resection. Preoperative plans and postoperative cone-beam computed tomography images were imported into an accuracy analysis system and aligned based on the anatomical structures to assess accuracy. The OT was recorded from the moment the foot pedal was pressed down until the bur reached the target depth. Statistical analyses were conducted using Kruskal-Wallis and Scheirer-Ray-Hare tests, with significance set at P < .05. RESULTS: RA-EMS exhibited significantly higher accuracy than DN- and SN-guided EMS in terms of platform, angular, and resection angular deviations (P < .05). Additionally, RA-EMS exhibited significantly higher accuracy than DN-guided EMS in resection length deviation (P < .05). Significant differences were also observed in OTs between the 3 approaches, with SN-guided EMS showing the shortest OT, followed by RA-EMS and DN-guided EMS. Differences in jaw types within the DN-guided EMS group were observed in terms of angular deviation (P < .05). CONCLUSIONS: All 3 treatment approaches demonstrated acceptable clinical accuracy and OT. RA-EMS exhibited superior accuracy, suggesting its potential application prospects in endodontics. Further high-quality clinical studies are warranted.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Chen C, Qin L, Zhang R, et al. Comparison of Accuracy and Operation Time in Robotic, Dynamic, and Static-Assisted Endodontic Microsurgery: An In Vitro Study. J Endod. 2024. PMID: 38838934. doi:10.1016/j.joen.2024.05.018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。