文献速递口腔修复与种植

3D打印与减材制造氧化锆冠的准确性、适配性与边缘质量:体外研究系统综述与Meta分析

Accuracy, adaptation and margin quality of monolithic zirconia crowns fabricated by 3D printing versus subtractive manufacturing technique: A systematic review and meta-analysis of in vitro studies.
PubMed 文献 · J Dent · 2024-05-19

本系统综述与Meta分析纳入9项体外研究(其中7项进入Meta分析),比较增材制造与减材制造氧化锆冠的准确性、边缘与内部适配性及边缘质量。全局Meta分析显示两种方法在真度(P<0.74,I2=90%)和边缘质量(P<0.61,I2=0%)上无显著差异,但打印系统亚组分析有显著效应(P<0.01)。多数冠区域无显著差异,仅边缘区 favoring 研磨冠、轴区 favoring 打印冠;两种方法精度与适配性均在临床可接受范围内。

要点

  • 增材制造氧化锆冠的真度和边缘质量与减材制造相当。
  • 打印系统亚组对真度有显著影响(P<0.01)。
  • 边缘区研磨冠更优,轴区打印冠更优,其余区域无差异。

核心结论

  • 增材制造氧化锆冠的真度和边缘质量与减材制造相当。
  • 两种技术均能使氧化锆冠的精度、内部间隙和边缘适合性处于临床可接受限度内。

研究设计与样本

  • 系统综述与Meta分析,遵循PRISMA-ScR指南,在Prospero注册(CRD42023452927)。
  • 检索PubMed、Scopus、Embase、Web of Science及手工检索截至2023年9月的文献。
  • 纳入比较打印与研磨氧化锆冠真度、精度、边缘与内部适配性及边缘质量的体外研究。
  • 排除种植体上冠、桥体、临时修复体、贴面或纯实验材料研究。
  • 共纳入9项研究进行描述性报告,其中7项进入Meta分析。

主要发现

  • 真度全局Meta分析显示打印与研磨氧化锆冠的均方根无显著差异(P<0.74,I2=90%)。
  • 边缘质量全局Meta分析显示无显著差异(P<0.61,I2=0%)。
  • 打印系统亚组分析显示显著效应(P<0.01)。
  • 冠区域Meta分析显示多数区域无显著差异,但边缘区 favoring 研磨冠、轴区 favoring 打印冠。
  • 精度和适配性方面两种方法均达临床可接受水平。

关键数值与推荐

  • 真度:打印与研磨氧化锆冠均方根无显著差异(P<0.74,I2=90%)。
  • 边缘质量:无显著差异(P<0.61,I2=0%)。
  • 打印系统亚组:对真度有显著效应(P<0.01)。
  • 冠区域:边缘区 favoring 研磨冠,轴区 favoring 打印冠。

临床怎么用

  • 3D打印可作为制造氧化锆冠的潜在替代方法,其真度和边缘质量与减材制造相当。
  • 选择打印系统时需注意其对真度存在显著亚组效应。
  • 两种方法制作的氧化锆冠精度、内部间隙和边缘适合性均在临床可接受范围内。

局限性

  • 仅纳入体外研究,结论需临床研究验证。
  • 真度Meta分析异质性高(I2=90%)。
  • 纳入研究数量较少(描述性9项,Meta分析7项)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The purpose of this systematic review and meta-analysis was to evaluate the accuracy (trueness and precision), marginal and internal adaptation, and margin quality of zirconia crowns made by additive manufacturing compared to subtractive manufacturing technology. METHODS: The investigation adhered to the PRISMA-ScR guidelines for systematic reviews and was registered at the Prospero database (n°CRD42023452927). Four electronic databases, including PubMed, Scopus, Embase, and Web of Science and manual search was conducted to find relevant studies published until September 2023. In vitro studies that assessed the trueness and precision, marginal and internal adaptation, and margin quality of printed crowns compared to milled ones were included. Studies on crowns over implants, pontics, temporary restorations, laminates, or exclusively experimental materials were excluded. RESULTS: A total of 9 studies were included in the descriptive reporting and 7 for meta-analysis. The global meta-analysis of the trueness (P<0.74,I2=90 %) and the margin quality (P<0.61,I2=0 %) indicated no significant difference between the root mean square of printed and milled zirconia crowns. The subgroup analysis for the printing system showed a significant effect (P<0.01). The meta-analysis of the crown areas indicated no significant difference in most of the areas, except for the marginal (favoring milled crowns) and axial (favoring printed crowns) areas. For precision and adaptation, both methods showed a clinically acceptable level. CONCLUSIONS: Additive manufacturing technology produces crowns with trueness and margin quality comparable to subtractive manufacturing. Both techniques have demonstrated the ability to produce crowns with precision levels, internal discrepancy, and marginal fit within clinically acceptable limits. CLINICAL SIGNIFICANCE: 3D printing emerges as a promising and potentially applicable alternative method for manufacturing zirconia crowns, as it shows trueness and margin quality comparable to restorations produced by the subtractive method.

来源:J Dent,查看原文。版权归原作者所有。

引用

  1. Silva SEGD, Silva NRD, Santos JVDN, et al. Accuracy, adaptation and margin quality of monolithic zirconia crowns fabricated by 3D printing versus subtractive manufacturing technique: A systematic review and meta-analysis of in vitro studies. J Dent. 2024. PMID: 38772449. doi:10.1016/j.jdent.2024.105089

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。