文献速递口腔修复与种植

种植支持单冠负载后一年咬合变化的系统评价与Meta分析

Occlusal changes on implant-supported single crowns with one year follow-up after loading: A systematic review and meta-analysis.
PubMed 文献 · J Dent · 2024-05-10

该系统评价纳入4项非随机对照临床试验,共133颗后牙区种植支持单冠,比较负载后不同随访期相对咬合力变化。结果显示负载后6至12个月相对咬合力变化量显著低于基线至6个月,且基线及3个月时对照天然牙相对咬合力显著高于种植单冠,半年后无显著差异。

要点

  • 种植单冠负载后相对咬合力随时间显著变化。
  • 负载后6至12个月相对咬合力变化量显著低于基线至6个月。
  • 建议第一年随访中密切监测并调整咬合。

核心结论

  • 种植支持单冠负载后相对咬合力随时间显著变化,提示修复戴入时定义的咬合概念会随时间改变或自然适应。

研究设计与样本

  • 系统评价与Meta分析,检索PubMed、Embase和Cochrane library,纳入4项非随机对照临床试验,共133颗后牙区种植支持单冠。

主要发现

  • 负载后6至12个月相对咬合力变化量显著低于基线至6个月(p < 0.05)。
  • 基线和3个月随访时对照天然牙相对咬合力显著高于种植支持单冠(p < 0.05),半年后无显著差异。

关键数值与推荐

  • 纳入标准为报告种植支持单冠(对颌为天然牙)在基线和负载后相对咬合力变化的研究,至少10例患者。
  • 所有分析种植支持单冠在负载时最大牙尖交错位轻咬无接触、重咬轻接触。
  • 相对咬合力定义为最大牙尖交错位时种植单冠或对照牙占全牙列总咬合力的百分比。

临床怎么用

  • 特定种植咬合概念(最大牙尖交错位轻咬无接触、重咬轻接触)的功能随时间有限,建议第一年随访中仔细监测并调整咬合。

局限性

  • 纳入研究均为非随机对照临床试验,证据等级受限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: This systematic review evaluated the occlusal changes after loading with implant-supported single crowns. SOURCES: An electronic literature search was conducted in PubMed, Embase and Cochrane library for randomized (RCTs) or non-randomized controlled clinical trials (CCTs), with a minimum of 10 patients. STUDY SELECTION: Studies reporting the occlusal force changes on implant-supported single crowns - with natural teeth as antagonist - measured at baseline and after loading periods were included. 4 CCTs including 133 ISCs in posterior sites were included for meta-analysis. All analyzed ISCs had no contact at a light bite and a light contact at a heavy bite in MIP at loading (baseline). DATA: The relative occlusal forces (ROFs) of each implant-supported single crown (ISC) or control tooth (CT) were extracted. ROFs were defined as percentage of the total occlusal force of the entire dentition at maximum intercuspal position (MIP). A meta-analysis was conducted to compare the ROF changes at different follow-up periods and the weighted mean differences in ROF between ISCs and CTs were pooled and analyzed. The amount of change in ROF was significantly lower in 6 to 12 months after loading comparing the follow-up period between baseline and 6 month (p < 0.05). At baseline and 3-month follow-up, CTs presented significant higher ROF than ISCs (p < 0.05), while no significant difference was found after half year following. CONCLUSIONS: This study showed that the ROF changes significantly over time after loading of ISCs. It might prove that the occlusal concept defined at the time of prosthetic delivery changes or adapts naturally over time. CLINICAL SIGNIFICANCE: The function of specific implant occlusal concept (no contact at a light bite and a light contact at a heavy bite in MIP) is limited over time and careful monitoring and occlusal adjustments should be recommendable during the first-year follow-up.

来源:J Dent,查看原文。版权归原作者所有。

引用

  1. Mao Z, Bleiel H, Beuer F, et al. Occlusal changes on implant-supported single crowns with one year follow-up after loading: A systematic review and meta-analysis. J Dent. 2024. PMID: 38734300. doi:10.1016/j.jdent.2024.105000

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。