文献速递口腔正畸

隐形矫治器用于牙本质发育不全患者正畸治疗一例

Orthodontic treatment of a patient with dentinogenesis imperfecta using a clear aligner system.
PubMed 文献 · J Am Dent Assoc · 2024-04-04

本文报告1例28岁女性牙本质发育不全(DGI)患者,表现为1 mm开𬌗、中切牙对刃𬌗及双侧Ⅲ类尖对尖磨牙关系,采用Invisalign隐形矫治器治疗3年半后获得正常覆盖覆盖及双侧Ⅰ类磨牙关系,下唇后退,且未对牙齿造成医源性损伤。作者认为隐形矫治器可能适合DGI患者。

要点

  • DGI患者牙体硬组织脆弱,正畸治疗存在风险,需谨慎选择矫治方式。
  • 本例使用Invisalign矫治3年半,达成正常覆盖覆盖与双侧Ⅰ类磨牙关系,无医源性牙损伤。
  • 隐形矫治器可减少牙齿受到的拉应力、减少粘接数量与面积,并通过全包裹塑料提供保护作用。

核心结论

  • 对DGI患者使用Invisalign隐形矫治器完成正畸治疗,获得正常覆盖覆盖与双侧Ⅰ类磨牙关系,且无医源性牙损伤,提示其可能为合适矫治选择。

研究设计与样本

  • 个案报告:1例28岁女性DGI患者,采用Invisalign隐形矫治器治疗,疗程3年半。

主要发现

  • 治疗前为1 mm开𬌗、中切牙对刃𬌗、双侧Ⅲ类尖对尖磨牙关系。
  • 治疗3年半后获得正常覆盖覆盖、双侧Ⅰ类磨牙关系,并伴下唇后退。
  • 治疗过程中未出现对患者牙齿的医源性损伤。

临床怎么用

  • 对DGI等牙体硬组织脆弱患者,可考虑隐形矫治器以减少拉应力与粘接面积,并借助全包裹提供保护,但需个体化评估。

局限性

  • 为单例个案报告,作者指出此前尚无相关研究,证据有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Orthodontic treatment for patients with dentinogenesis imperfecta (DGI) can be risky because of the fragility of their dental hard tissue. Although the Invisalign (Align Technology) clear aligner system should be a suitable orthodontic appliance for patients with DGI, to the authors' knowledge, there has been no related research. CASE DESCRIPTION: A 28-year-old woman with DGI sought treatment with a 1 mm open bite, edge-to-edge occlusion of the central incisors, and a bilateral Class III cusp-to-cusp molar relationship. Invisalign was applied for her treatment, and after 3 and one-half years of orthodontic therapy, a normal overjet and overbite were achieved, accompanied by retraction of the lower lip as well as a bilateral Class I molar relationship. In addition, there was no iatrogenic injury to the patient's teeth. PRACTICAL IMPLICATIONS: The Invisalign system may be a suitable orthodontic appliance for patients with DGI because clear aligners lessen the tensile stress to the teeth, decrease the number and area of bonds to the teeth, and offer protective effects through a full wrap of plastic that covers the crowns of the teeth.

来源:J Am Dent Assoc,查看原文。版权归原作者所有。

引用

  1. Meng C, Le D, Wang X, et al. Orthodontic treatment of a patient with dentinogenesis imperfecta using a clear aligner system. J Am Dent Assoc. 2024. PMID: 38573273. doi:10.1016/j.adaj.2024.01.007

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。