面部扫描仪测量咬合垂直距离的可靠性
研究纳入20名全牙列志愿者,用数字卡尺和面部扫描仪在最大牙尖交错位及垂直距离增加2、4、6mm时测量面部标志点距离。结果显示数字与临床测量高度相关(r>0.93,p<0.001),ICC优秀,Bland-Altman差异1.7%,两种方法可互换,面部扫描可准确测量咬合垂直距离并检测微小变化。
要点
- 面部扫描仪测量咬合垂直距离与临床卡尺测量高度一致,可互换使用。
- 数字方法能检测咬合垂直距离小至2mm的变化。
- 该技术有望用于CAD-CAM义齿的颌位关系记录。
核心结论
- 面部扫描结合3D网格处理软件可准确测量咬合垂直距离,并能检测其微小变化。
研究设计与样本
- 纳入20名全牙列志愿者(平均年龄30.0±10.7岁),用数字卡尺和面部扫描仪(Obiscanner)测量,在最大牙尖交错位及垂直距离增加2、4、6mm时共获得120次测量(临床60次,数字60次),由两名评估者完成。
主要发现
- 数字与临床测量的平均差异范围为0.054±0.14mm至0.203±0.13mm。
- 所有参数强相关(r>0.93;p<0.001),ICC估计显示优秀可靠性。
- Bland-Altman图显示垂直测量数字与临床差异为1.7%。
- 回归分析显示两种方法无显著比例差异,可互换使用。
关键数值与推荐
- 数字与临床测量强相关(r>0.93;p<0.001)。
- ICC估计显示优秀可靠性,重复试验结果一致。
- Bland-Altman图垂直测量差异为1.7%。
临床怎么用
- 可将面部扫描测量咬合垂直距离的方法纳入CAD-CAM义齿的临床工作流程。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: This study evaluated the reliability of a face scanner in measuring the vertical dimension of occlusion (VDO). METHODS: Fully dentate volunteers (n = 20; mean-age = 30.0 ± 10.7 years) were recruited. Clinical facial measurements were obtained using a digital caliper and a face scanner (Obiscanner, Fifthingenium, Italy). The scans were imported into a mesh-processing software, and the distances were measured digitally. Measurements were obtained for each participant with the jaws positioned in maximal intercuspation (MI) and with increased vertical distances of 2, 4, and 6 mm. Vertical and horizontal measures were obtained using facial anatomical landmarks: Glabella (GL), Pronasale (PrN), Subnasale (SbN), inferior border of the right and left Alare, Labiale superius (Ls), right and left Cheilion (Ch), Soft Pogonion (SPg), right and left Tragus of the ear (Tr), for all selected vertical positions. Data analysis included intra-class correlation coefficient (ICC), pairwise comparison tests, Bland-Altman plots, and Passing-Bablok regression. RESULTS: 120 VDO measurements (clinical=60, digital=60) were recorded by two independent evaluators. Mean differences between digital and clinical measurements ranged from 0.054 ± 0.14 mm to 0.203 ± 0.13 mm. All parameters were strongly correlated (r > 0.93; p < 0.001). ICC estimates revealed excellent reliability, and the measuring procedure yielded the same results on repeated trials irrespective of the raters and measurement methods. Bland-Altman plots revealed a difference, between digital and clinical measurements, of 1.7 % for the vertical measurements. Regression analysis revealed no significant proportional difference between the two methods, so both can be used interchangeably. CONCLUSIONS: The findings of this study demonstrate that VDO can be measured accurately from face scans using 3D mesh-processing software and that even small changes in the VDO could be detected using the digital methods. CLINICAL SIGNIFICANCE: Findings provide evidence about the reliability of a digital method for jaw relation registrations and may be applied towards incorporating this method into clinical workflows for computer-aided-design/ computer-assisted-manufacturing (CAD-CAM) dentures.
引用
- Srinivasan M, Berisha F, Bronzino I, et al. Reliability of a face scanner in measuring the vertical dimension of occlusion. J Dent. 2024. PMID: 38679136. doi:10.1016/j.jdent.2024.105016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。