口腔手术黏膜闭合用合成聚酰胺缝线的前瞻性多中心国际单臂队列研究:MUCODA研究
本研究为前瞻性、双中心、国际、单臂观察性研究,纳入105例接受不同牙科手术干预后使用不可吸收尼龙单丝缝线闭合黏膜的患者。主要目标为拆线前联合术后并发症发生率,结果为1.9%(2例肿胀),满足非劣效性上限21.9%。结论认为该缝线安全且适合口腔黏膜闭合。
要点
- 并发症发生率低(1.9%),仅2例肿胀,满足预设非劣效性上限21.9%。
- 阻生第三磨牙拔除患者疼痛持续时间最长(6天),平均疼痛水平最高(VAS 35.33±30.45)。
- 术者缝线操作评价为很好至优秀,患者满意度高, dentist报告愈合优秀。
核心结论
- 不可吸收尼龙单丝缝线用于牙拔除、种植及阻生第三磨牙拔除等口腔手术后的黏膜闭合是安全的,且相当适合。
研究设计与样本
- 前瞻性、双中心、国际、单臂观察性研究,共纳入105例患者,使用不可吸收缝线闭合黏膜。
主要发现
- 并发症发生率为1.9%,发生2例肿胀。
- 术后疼痛持续1.61±1.42天,平均疼痛水平为20.98±22.60(VAS)。
- 阻生第三磨牙拔除患者疼痛持续时间最长(6天),平均疼痛水平最高为35.33±30.45(VAS)。
- 平均拆线时间为7.56±2.09天,患者满意度高,牙医报告愈合优秀。
- 仅种植患者评估美学外观,术后5个月口腔外科医生评分为96.19±3.79分(最小80,最大100)。
关键数值与推荐
- 主要终点为拆线前联合术后并发症发生率,采用95%置信区间(Agresti-Coull法)证明非劣效性,预设上限为21.9%。
- 缝线细菌分析显示F. nucleatum是最常见的菌种。
临床怎么用
- 在常规临床实践中,该不可吸收尼龙单丝缝线可用于牙拔除、种植及阻生第三磨牙拔除等口腔手术后的黏膜闭合。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The aim was to collect different clinical parameters systematically and proactively regarding safety, effectiveness, and performance of a nylon monofilament suture under routine clinical practice for oral surgery. METHODS: The study design was prospective, bicentric, international, single-armed, and observational. A non-absorbable suture was applied to close the mucosa after different dental surgical interventions. Main objective was the incidence of combined postoperative complications until suture removal. The 95 % Confidence Interval (Agresti-Coull method) was used to prove the non-inferiority with a pre-specified upper margin of 21.9 %. Secondary variables were intraoperative suture handling, patient pain and satisfaction, wound healing, aesthetic appearance, and bacterial contamination. RESULTS: 105 patients were enrolled. Complication rate was low (1.9 %), 2 swellings occurred. Pain was present for 1.61 days ± 1.42 after various dental interventions with an average pain level of 20.98 ± 22.60 (VAS). Patients with impacted third molar extraction showed the longest pain duration (6 days) combined with the highest mean pain level of 35.33 ± 30.45 (VAS). Intraoperative suture handling was very good to excellent. Suture removal was done after an average duration of 7.56 ± 2.09 days. Patient's satisfaction was high, and an excellent wound healing was reported by the dentists. Aesthetic appearance only performed in implant patients was rated by oral surgeons with an average of 96.19 ± 3.79 points [min. 80 - max. 100] at 5 months postoperatively. Thread bacterial analysis showed that F. nucleatum was the most present species. CONCLUSIONS: Our findings indicate that the non-absorbable, nylon-based monofilament suture used is safe and quite suitable for oral mucosal closure after various dental surgical interventions such as tooth extraction, implant placement and impacted third molar extraction. CLINICAL SIGNIFICANCE: This study showed the safe use of a non-absorbable, nylon-based monofilament suture for different oral surgical interventions under daily routine clinical practice.
引用
- García-González S, Aboul-Hosn Centenero S, Baumann P, et al. Prospective, multi-centric, international, single-arm, cohort study to assess a synthetic polyamide suture material in oral surgery to close the mucosa - MUCODA study. J Dent. 2024. PMID: 38490322. doi:10.1016/j.jdent.2024.104922
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。