文献速递口腔修复与种植

保留骨膜的改良GBR与传统GBR用于种植体周骨增量的回顾性比较

Guided bone regeneration for peri-implant augmentation: A retrospective study comparing two surgical techniques with a mean follow-up of 26 months.
PubMed 文献 · Clin Oral Implants Res · 2024-03-11

本研究回顾2015至2021年后牙区接受种植体周骨增量患者,比较保留骨膜联合DBBM的改良GBR(A组)与传统GBR(B组)。共纳入98例患者114枚种植体,经倾向评分匹配分析,两组种植体存活率、硬组织尺寸变化、边缘骨吸收及种植体周参数均无显著差异。

要点

  • 改良GBR组种植体存活率95.74%,传统GBR组95.00%。
  • 术后6个月水平厚度中位数A组0.87 mm,B组0.98 mm(p=.937)。
  • 垂直高度、边缘骨吸收及种植体周参数两组间无显著差异。

核心结论

  • 在研究的局限性内,保留骨膜联合DBBM的改良GBR技术可能是矫正磨牙和前磨牙区种植体周围骨缺损的可行替代方案。

研究设计与样本

  • 回顾性研究,纳入2015至2021年后牙区接受种植体周骨增量的98例患者共114枚种植体。
  • A组采用保留骨膜的改良GBR技术,B组采用传统GBR,并进行倾向评分匹配及敏感性分析。

主要发现

  • 随访期间种植体存活率A组95.74%,B组95.00%。
  • 术后6个月水平厚度中位数A组0.87 mm(IQ1-IQ3=0.00-1.75 mm),B组0.98 mm(IQ1-IQ3=0.00-1.89 mm),组间p=.937。
  • 垂直高度两组间无统计学显著差异(p=.758)。
  • 加载后平均随访时间A组25.83±12.93个月,B组27.47±21.29个月(p=.761)。
  • 边缘骨吸收和种植体周参数两组间具有可比性。

临床怎么用

  • 在后牙区种植体周骨缺损矫正中,可考虑采用保留骨膜的改良GBR作为传统GBR的替代方案。

局限性

  • 回顾性研究设计存在固有局限性,结论需在解释时考虑研究限制。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To introduce a modified guided bone regeneration (GBR) technique using intact periosteum and deproteinized bovine bone mineral (DBBM) for peri-implant augmentation and compare the clinical outcomes with those of conventional GBR. MATERIALS AND METHODS: Patients who received peri-implant augmentation in posterior sites between 2015 and 2021 were reviewed in this study. Group A was treated with a modified GBR technique, and Group B was treated with conventional GBR. For group comparison, propensity score matching was performed with a sensitivity analysis. The implant survival rate, dimensional changes in hard tissue, marginal bone loss (MBL), and peri-implant parameters were evaluated. RESULTS: In total, 114 implants from 98 patients were included. The implant survival rates were 95.74% in Group A and 95.00% in Group B during the follow-up period. At 6 months, the median horizontal thickness was recorded at 0.87 mm (IQ1-IQ3 = 0.00-1.75 mm) in Group A, exhibiting a relatively lower value compared to the corresponding measurement of 0.98 mm (IQ1-IQ3 = 0.00-1.89 mm) in Group B (p = .937). Vertical height displayed no statistically significant intergroup difference between the two groups (p = .758). The mean follow-up period was 25.83 ± 12.93 months after loading in Group A and 27.47 ± 21.29 months in Group B (p = .761). MBL and peri-implant parameters were comparable between the two groups. CONCLUSIONS: Within the limitations of this study, the modified GBR technique using intact periosteum and DBBM grafting might be a viable alternative to correct bone defects around implants in molar and premolar sites.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Liu Y, Lan D, Gao J, et al. Guided bone regeneration for peri-implant augmentation: A retrospective study comparing two surgical techniques with a mean follow-up of 26 months. Clin Oral Implants Res. 2024. PMID: 38467593. doi:10.1111/clr.14254

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。