机器人手术用于牙种植体植入的精度:系统综述与Meta分析

Accuracy of robotic surgery for dental implant placement: A systematic review and meta-analysis.
PubMed 文献 · Clin Oral Implants Res · 2024-03-22

该研究系统检索了PubMed、Embase和Cochrane CENTRAL(截至2023年10月25日),纳入8项临床研究(109例患者、242枚种植体)和13项临床前研究。Meta分析显示临床研究中平台偏差、根尖偏差和角度偏差的合并值分别为0.68 mm、0.67 mm和1.69°,未报告不良事件。结论认为机器人手术用于牙种植体植入显示出合适的种植体位置精度,且无明显危害报告。

要点

  • 临床研究中机器人种植的合并平台偏差为0.68 mm(95%CI 0.57–0.79)。
  • 临床研究中合并根尖偏差为0.67 mm(95%CI 0.58–0.75)。
  • 临床研究中合并角度偏差为1.69°(95%CI 1.25–2.12°)。

核心结论

  • 在本次系统综述的局限性范围内,机器人手术用于牙种植体植入显示出合适的种植体位置精度,且未报告明显危害。
  • 机器人系统和相关临床研究均应进一步开发。

研究设计与样本

  • 系统综述与Meta分析,检索PubMed、Embase和Cochrane CENTRAL(截至2023年10月25日)。
  • 纳入报告机器人手术种植精度的模型研究或临床研究,对象为缺牙或无保留价值牙的患者。
  • 纳入8项临床研究(109例患者、242枚种植体)和13项临床前研究,并评估临床研究的偏倚风险。

主要发现

  • 临床研究中合并平台偏差、根尖偏差和角度偏差分别为0.68(95%CI 0.57–0.79)mm、0.67(95%CI 0.58–0.75)mm和1.69(95%CI 1.25–2.12)°。
  • 部分牙列缺失与全牙列缺失患者种植体精度差异无统计学意义。
  • 模型研究中合并平台偏差、根尖偏差和角度偏差分别为0.72(95%CI 0.58–0.86)mm、0.90(95%CI 0.74–1.06)mm和1.46(95%CI 1.22–1.70)°。
  • 未报告不良事件。

临床怎么用

  • 机器人手术种植可达到临床研究中合并平台偏差0.68 mm、根尖偏差0.67 mm、角度偏差1.69°的精度水平。
  • 现有证据未报告明显危害,但需进一步开发机器人系统并开展临床研究。

局限性

  • 结论受本系统综述的局限性约束。
  • 需进一步开发机器人系统并开展更多临床研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To systematically analyze the accuracy of robotic surgery for dental implant placement. MATERIALS AND METHODS: PubMed, Embase, and Cochrane CENTRAL were searched on October 25, 2023. Model studies or clinical studies reporting the accuracy of robotic surgery for dental implant placement among patients with missing or hopeless teeth were included. Risks of bias in clinical studies were assessed. Meta-analyses were undertaken. RESULTS: Data from 8 clinical studies reporting on 109 patients and 242 implants and 13 preclinical studies were included. Positional accuracy was measured by comparing the implant plan in presurgery CBCT and the actual implant position in postsurgery CBCT. For clinical studies, the pooled (95% confidence interval) platform deviation, apex deviation, and angular deviation were 0.68 (0.57, 0.79) mm, 0.67 (0.58, 0.75) mm, and 1.69 (1.25, 2.12)°, respectively. There was no statistically significant difference between the accuracy of implants placed in partially or fully edentulous patients. For model studies, the pooled platform deviation, apex deviation, and angular deviation were 0.72 (0.58, 0.86) mm, 0.90 (0.74, 1.06) mm, and 1.46 (1.22, 1.70)°, respectively. No adverse event was reported. CONCLUSION: Within the limitation of the present systematic review, robotic surgery for dental implant placement showed suitable implant positional accuracy and had no reported obvious harm. Both robotic systems and clinical studies on robotic surgery for dental implant placement should be further developed.