PubMed 文献 · J Endod · 2024-03-01

本研究评估不同终末冲洗方案去除根管内氢氧化钙后,AH Plus封闭剂与根管牙本质的推出粘结强度(POBS)及粘接界面质量。40个根管随机分为蒸馏水、1%次氯酸钠、17% EDTA、17% EDTA+1%次氯酸钠四组。结果显示单纯EDTA冲洗对粘结强度有负面影响,而EDTA后接次氯酸钠冲洗与蒸馏水效果相似,界面均匀无间隙且封闭剂标签形成更多。

要点

  • 单纯17% EDTA冲洗去除氢氧化钙会降低AH Plus的推出粘结强度。
  • EDTA后接1%次氯酸钠冲洗与蒸馏水效果相当,界面均匀无间隙。
  • EDTA+次氯酸钠组封闭剂标签形成数量显著高于其他组。

核心结论

  • 终末冲洗使用EDTA去除氢氧化钙对AH Plus与根管牙本质的推出粘结强度有负面影响。
  • EDTA后接次氯酸钠冲洗可获得与蒸馏水相似的粘结强度和更优的粘接界面质量。

研究设计与样本

  • 体外研究,40个根管随机分为4组(n=10),分别用蒸馏水、1% NaOCl、17% EDTA、17% EDTA+1% NaOCl冲洗去除氢氧化钙。
  • 根管充填AH Plus和牙胶后7天,切片进行推出粘结强度测试和扫描电镜观察粘接界面。
  • 使用方差分析和Tukey检验分析POBS,Kruskal-Wallis和Mann-Whitney检验分析粘接界面(α=0.05)。

主要发现

  • 蒸馏水、1% NaOCl和17% EDTA+1% NaOCl组的POBS值相似,且根尖三分之一处的POBS值高于其他三分之一(P < .05)。
  • 蒸馏水、1% NaOCl和17% EDTA+1% NaOCl组观察到均匀无间隙的粘接界面,蒸馏水与17% EDTA组间有差异(P < .05)。
  • 蒸馏水和17% EDTA+1% NaOCl组显示出更高的封闭剂标签形成(P < .05)。

关键数值与推荐

  • POBS值:蒸馏水、1% NaOCl、17% EDTA+1% NaOCl组相似,根尖三分之一处更高(P < .05)。
  • 粘接界面:蒸馏水与17% EDTA组间有差异(P < .05)。
  • 封闭剂标签形成:蒸馏水和17% EDTA+1% NaOCl组更高(P < .05)。

临床怎么用

  • 去除根管内氢氧化钙时,避免单独使用17% EDTA作为终末冲洗,因其降低AH Plus粘结强度。
  • 推荐使用17% EDTA后接1% NaOCl冲洗,可获得均匀无间隙的粘接界面和更多封闭剂标签。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: To evaluate the push-out bond strength (POBS) of AH Plus sealer to root dentin and the adhesive interface quality after calcium hydroxide (Ca(OH)2) intracanal dressing removal with different final irrigation protocols. METHOD: After root canal instrumentation and irrigation, 40 root canals were filled with Ca(OH)2 and sealed. After 14 days, the specimens were randomly distributed according to the irrigation protocols for Ca(OH)2 removal (n = 10): GH2O (control) - distilled water; GNaOCl - 1% NaOCl; GEDTA - 17% EDTA; GEDTA + NaOCl - 17% EDTA + 1% NaOCl. The root canals were filled with AH Plus sealer and gutta-percha. After 7 days, the roots were sectioned into dentin slices and submitted to POBS test and analysis of the adhesive interface under scanning electron microscope. The POBS data were statistically evaluated (analysis of variance and Tukey test). The Kruskal-Wallis and Mann-Whitney tests were used to analyze the adhesive interface (α = 0.05). RESULTS: GH2O, GNaOCl, and GEDTA + NaOCl had similar POBS values, with higher values on the apical third, in comparison with other thirds (P < .05). A homogeneous and free-of-gaps adhesive interface was observed for GH2O, GNaOCl, and GEDTA + NaOCl, with difference between GH2O and GEDTA (P < .05). GH2O and GEDTA + NaOCl presented higher sealer tags formation (P < .05). CONCLUSION: The final rinse with EDTA for Ca(OH)2 dressing removal had a negative effect on the POBS of the filling material to root dentin. The use of EDTA followed by NaOCl had results similar to the distilled water, providing uniform and free-of-gaps adhesive interface, and a higher number of sealer tags.