实时三维动态导航用于根管治疗后桩道预备的体外研究
本研究将54颗上颌磨牙分为三维动态导航(3D-DNS)组和徒手(FH)组,比较桩道预备的准确性与效率。结果显示3D-DNS组三维偏差和角度偏斜显著更小,操作时间更短,且无牙本质剩余厚度(RDT)<1 mm的牙齿,而FH组有6/27颗出现RDT<1 mm。结论认为3D-DNS用于桩道预备可行,可提高准确性和效率。
要点
- 3D-DNS组桩道预备的三维偏差和角度偏斜均显著小于徒手组(P<.05)。
- 3D-DNS组操作时间显著短于徒手组(P<.05)。
- 3D-DNS组无RDT<1 mm的牙齿,徒手组有6/27颗出现RDT<1 mm。
核心结论
- 在本体外研究限制下,3D-DNS用于根管治疗后桩道预备是可行的,能提高准确性和效率。
- 动态导航系统有望成为桩道预备安全可靠的技术。
研究设计与样本
- 体外研究,将54颗上颌磨牙分为3D-DNS组(n=27)和徒手(FH)组(n=27)。
- 术前术后拍摄锥形束CT(CBCT),在X-guide软件中进行虚拟规划。
- 记录三维偏差、角度偏斜、剩余牙本质厚度(RDT)、操作时间和并发症总数。
主要发现
- 所有54颗牙齿均完成桩道预备。
- 3D-DNS组三维偏差和角度偏斜显著少于FH组(均P<.05)。
- 3D-DNS组操作时间显著少于FH组(P<.05)。
- 3D-DNS组无牙齿RDT<1 mm,FH组有6/27颗牙齿RDT<1 mm。
- 两组并发症总数无差异(P>.05)。
关键数值与推荐
- 3D-DNS组与FH组在三维偏差和角度偏斜上差异显著(P<.05)。
- 3D-DNS组操作时间显著短于FH组(P<.05)。
- FH组6/27颗牙齿桩道预备后RDT<1 mm,3D-DNS组为0颗。
临床怎么用
- 对于根管治疗后需桩道预备的牙齿,可考虑使用3D-DNS以提高预备准确性。
- 3D-DNS可能有助于减少剩余牙本质厚度不足的风险。
局限性
- 本研究为体外研究,结论需进一步临床验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The aim of this study was to investigate the feasibility of a real-time three-dimensional dynamic navigation system (3D-DNS) for post space preparation (PSP) in root canal-treated teeth and to compare the accuracy and efficiency of 3D-DNS to freehand (FH) for PSP. METHODS: Fifty-four maxillary molars were divided into two groups: 3D-DNS (n = 27) and FH group (n = 27). Cone beam computed tomography (CBCT) scans were taken preoperatively and postoperatively. The drilling path for the PSP was virtually planned in the preoperative CBCT scan in the X-guide software (X-Nav Technologies, Lansdale, PA). For the 3D-DNS group, the PSP drilling was conducted under dynamic navigation. The 3D deviations and angular deflections were calculated. The residual dentin thickness (RDT) was determined after PSP. The operation time and the total number of mishaps were recorded. Shapiro-Wilk, t-test or Mann-Whitney rank sum, weighted Cohen's kappa, and Fisher exact tests were used (P < .05). RESULTS: The PSP was completed in all samples (54/54). The 3D-DNS was more accurate than the FH, with significantly fewer 3D deviations and angular deflections (all, P < .05). The 3D-DNS required less operating time than the FH (P < .05). For the 3D-DNS, no teeth had RDT < 1 mm, whereas 6/27 in the FH showed RDT < 1 mm after the PSP. There was no difference in the total number of mishaps (P > .05). CONCLUSION: Within the limitations of this in vitro study, the 3D-DNS is feasible for PSP. The 3D-DNS improved the accuracy and efficiency of PSP. The dynamic navigation system can potentially become a safe and reliable technology for PSP.
引用
- Martinho FC, Qadir SJ, Price JB, et al. Real-Time Three-dimensional Dynamic Navigation for Post Space Preparation in Root Canal-Treated Teeth: An In vitro Study. J Endod. 2024. PMID: 38522577. doi:10.1016/j.joen.2024.03.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。