文献速递牙体牙髓病

GentleWave系统在最小器械预备前后去除下颌磨牙近中根生物膜的效果:一项离体研究

Efficacy of the GentleWave System in the removal of biofilm from the mesial roots of mandibular molars before and after minimal instrumentation: An ex vivo study.
PubMed 文献 · Int Endod J · 2024-02-19

该离体研究比较了GentleWave系统(GWS)在未器械预备与最小器械预备根管系统中去除粪肠球菌生物膜的效果。34颗下颌磨牙分为阴性对照、阳性对照、未器械+GWS组和最小器械+GWS组,接种粪肠球菌3周后处理。结果显示两实验组均显著降低细菌量,但两组间无显著差异,提示GWS在未器械根管中即可有效消毒。

要点

  • GWS在未器械预备根管中去除粪肠球菌生物膜效果显著优于阳性对照。
  • 最小器械预备后使用GWS与未器械预备使用GWS的杀菌效果无显著差异。
  • GWS可作为未器械根管系统的有效消毒方案,且不产生牙本质碎屑。

核心结论

  • GWS在未器械预备的根管系统上使用可有效去除生物膜,且不形成牙本质碎屑。

研究设计与样本

  • 离体研究,34颗下颌磨牙分配至阴性对照(n=5)、阳性对照(n=5)、未器械+GWS组(n=12)和最小器械+GWS组(n=12)。
  • 24颗近中根为Vertucci II型配置的样本按工作长度和根管构型匹配后分入两组实验组。
  • 样本接种粪肠球菌3周后,未器械组直接使用GWS,最小器械组预备至20/06v后使用GWS,采用CFU和SEM分析。

主要发现

  • 阳性对照组、未器械+GWS组和最小器械+GWS组的Log10(CFU/mL)分别为7.41±0.53、3.41±1.54和3.21±1.54。
  • 两实验组较阳性对照组均显著降低活粪肠球菌数量(未器械+GWS组p=.0001,最小器械+GWS组p<.0001)。
  • 两实验组之间无显著差异(p<.05)。

临床怎么用

  • 对于未行器械预备的根管系统,可考虑使用GWS进行消毒以去除生物膜。
  • 最小器械预备至20/06v后使用GWS与未器械预备直接使用GWS的杀菌效果相当。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To compare the efficacy of Enterococcus faecalis biofilm removal using the GentleWave System (GWS) (Sonendo Inc, CA) on non-instrumented versus minimally instrumented root canal systems. METHODOLOGY: Thirty-four mandibular molars were autoclaved and allocated to four groups: Negative control (n = 5); positive control (n = 5); Group 1: non-instrumentation + GWS (NI + GWS) (n = 12); and Group 2: minimal instrumentation + GWS (MI + GWS) (n = 12). Of 34 samples, 24 samples with Vertucci type 2 configuration within the mesial root of each sample were allocated to Groups 1 and 2 and then matched based on the working length and root canal configuration. After inoculation of samples with E. faecalis for 3 weeks, the GWS was used on Group 1 without any instrumentation and Group 2 after instrumentation of mesial canals until size 20/06v. CFU and SEM analysis were used. RESULTS: Log10 (CFU/mL) from the positive control, and Group 1 and 2 were 7.41 ± 0.53, 3.41 ± 1.54, and 3.21 ± 1.54, respectively. Both groups showed a statistically significant difference in the reduction of viable E. faecalis cells compared to the positive control (Group 1 [p = .0001] and Group 2 [p < .0001]), whilst showing no significant difference between the two tested groups (p < .05). CONCLUSION: The use of GWS on the non-instrumented root canal system could be an effective disinfection protocol in removing the biofilm without dentin debris formation.

来源:Int Endod J,查看原文。版权归原作者所有。

引用

  1. Kim KH, Lévesque C, Malkhassian G, et al. Efficacy of the GentleWave System in the removal of biofilm from the mesial roots of mandibular molars before and after minimal instrumentation: An ex vivo study. Int Endod J. 2024. PMID: 38374488. doi:10.1111/iej.14044

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。