文献速递口腔修复与种植

新型三步法钛种植体去污方案的疗效:体外与体内研究

Efficacy of a novel three-step decontamination protocol for titanium-based dental implants: An in vitro and in vivo study.
PubMed 文献 · Clin Oral Implants Res · 2023-12-22

本研究评估了机械与化学去污方法联合新型生物膜基质破坏策略对钛表面的清洁效果。体外实验显示Er:YAG激光清洁最佳且损伤小,0.95%次氯酸钠(NaOCl)减少生物膜最有效。体内模型中Er:YAG激光+0.2%聚维酮碘(PVPI)+0.95% NaOCl联合方案实现约99%生物膜根除,为可靠去污方案。

要点

  • Er:YAG激光清洁钛表面效果最佳且损伤最小。
  • 0.95% NaOCl减少体外和体内生物膜最有效。
  • Er:YAG激光+PVPI 0.2%+NaOCl 0.95%可实现约99%生物膜根除。

核心结论

  • Er:YAG激光+PVPI 0.2%+NaOCl 0.95%可作为钛表面可靠去污方案,消除微生物生物膜且不损伤种植体表面。

研究设计与样本

  • 体外实验使用增材制造的钛 discs,覆盖多微生物生物膜后采用机械或化学去污方案处理。
  • 体内实验采用口内装置生物膜模型,测试体外筛选出的最佳机械/化学联合方案。

主要发现

  • Er:YAG激光处理显示最佳表面清洁效果,生物膜去除且对表面损伤最小,钛释放更少,腐蚀稳定性好,成纤维细胞再黏附改善。
  • 0.95% NaOCl是减少体外和体内生物膜最有希望的试剂,与PVPI 0.2%预处理破坏生物膜基质联用时更有效。
  • Er:YAG激光后接PVPI 0.2%+NaOCl 0.95%联合方案促进粗糙钛表面有效去污,是唯一导致约99%生物膜根除的方案。

临床怎么用

  • 对于钛种植体表面去污,可考虑采用Er:YAG激光联合PVPI 0.2%预处理和NaOCl 0.95%的序贯方案。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: The aim of the study was to evaluate several mechanical and chemical decontamination methods associated with a newly introduced biofilm matrix disruption strategy for biofilm cleaning and preservation of implant surface features. MATERIALS AND METHODS: Titanium (Ti) discs were obtained by additive manufacturing. Polymicrobial biofilm-covered Ti disc surfaces were decontaminated with mechanical [Ti curette, Teflon curette, Ti brush, water-air jet device, and Er:YAG laser] or chemical [iodopovidone (PVPI) 0.2% to disrupt the extracellular matrix, along with amoxicillin; minocycline; tetracycline; H2 O2 3%; chlorhexidine 0.2%; NaOCl 0.95%; hydrocarbon-oxo-borate-based antiseptic] protocols. The optimal in vitro mechanical/chemical protocol was then tested in combination using an in vivo biofilm model with intra-oral devices. RESULTS: Er:YAG laser treatment displayed optimum surface cleaning by biofilm removal with minimal deleterious damage to the surface, smaller Ti release, good corrosion stability, and improved fibroblast readhesion. NaOCl 0.95% was the most promising agent to reduce in vitro and in vivo biofilms and was even more effective when associated with PVPI 0.2% as a pre-treatment to disrupt the biofilm matrix. The combination of Er:YAG laser followed by PVPI 0.2% plus NaOCl 0.95% promoted efficient decontamination of rough Ti surfaces by disrupting the biofilm matrix and killing remnants of in vivo biofilms formed in the mouth (the only protocol to lead to ~99% biofilm eradication). CONCLUSION: Er:YAG laser + PVPI 0.2% + NaOCl 0.95% can be a reliable decontamination protocol for Ti surfaces, eliminating microbial biofilms without damaging the implant surface.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Costa RC, Takeda TTS, Dini C, et al. Efficacy of a novel three-step decontamination protocol for titanium-based dental implants: An in vitro and in vivo study. Clin Oral Implants Res. 2023. PMID: 38131526. doi:10.1111/clr.14224

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。