文献速递口腔修复与种植

零回波时间MRI与锥形束CT测量无牙颌种植位点颌骨的一致性:离体研究

Jawbone measurements of edentulous sites related to implant planning using magnetic resonance imaging compared to cone beam computed tomography: An ex vivo study.
PubMed 文献 · Clin Oral Implants Res · 2023-11-20

观察者间ICC>0.95;骨高度测量两者无显著差异;ZTE-MRI测得的骨宽度和面积显著小于CBCT。

要点

  • ZTE-MRI与CBCT测量牙槽骨高度结果基本一致。
  • ZTE-MRI测得的骨宽度和面积系统性小于CBCT。
  • 观察者间对高度、宽度和面积测量的一致性高(ICC>0.95)。

核心结论

  • CBCT与MRI测量牙槽骨高度基本等效,且与MRI灰度选择无关。
  • ZTE-MRI导致骨宽度和面积的估计值小于CBCT。

研究设计与样本

  • 使用CBCT和零回波时间MRI(ZTE-MRI)成像,生成与种植规划相关的冠状面。
  • ZTE-MRI图像还以灰度反转(INV MRI)形式呈现。
  • 三名观察者测量骨高度、距牙槽嵴5 mm处的骨宽度及从宽度测量处至牙槽嵴顶的骨面积。

主要发现

  • 骨高度、宽度和骨面积的观察者间ICC均>0.95。
  • 骨高度:观察者(p=0.14)和图像类型(p=0.60)均无显著差异。
  • 骨宽度:观察者(p=0.14)非显著因素,ZTE-MRI估计值显著且系统性小于CBCT(p≤0.001)。
  • 骨面积:观察者(p=0.06)非显著因素,ZTE-MRI估计值显著小于CBCT(p≤0.001)。

临床怎么用

  • 在种植规划中,MRI可用于评估牙槽骨高度,与CBCT结果基本一致。
  • 需注意ZTE-MRI对骨宽度和面积的测量值可能小于CBCT,解读时应考虑此差异。

局限性

  • 离体研究,结果需在临床环境中进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIM: To compare measurements on images obtained by magnetic resonance imaging (MRI) and cone beam CT (CBCT) for height, width, and area in alveolar bone sites in human jaw specimens. MATERIAL AND METHODS: Forty edentulous alveolar posterior sites in human cadaver specimens were imaged using CBCT scanners, and with zero-echo-time MRI (ZTE-MRI). Semi-automatic volume registration was performed to generate representative coronal sections of the sites related to implant planning. ZTE-MRI sections were also presented after grayscale inversion (INV MRI). Three observers measured bone height, bone width 5 mm from the alveolar crest, and bone area stretching from the width measurement to the top of the alveolar crest in the images. Interobserver agreement was assessed by intra-class correlation coefficients (ICC). The measurements were analyzed using two-way repeated measures ANOVA factoring observer and image type. RESULTS: ICC was >0.95 for bone height, width, and bone area. No significant differences among observers (p = 0.14) or image type (p = 0.60) were found for bone height. For bone width, observer (p = 0.14) was not a significant factor, while ZTE-MRI produced width estimates that were significantly different and systematically smaller than CBCT-based estimates (p ≤ 0.001). Observer (p = 0.06) was not a significant factor regarding the bone area measurements, contrary to the imaging type where ZTE-MRI led to significantly smaller area estimates than CBCT (p ≤ 0.001). CONCLUSION: Bone height measurements were essentially equivalent using CBCT and MRI. This was found regardless of grayscale choice for the MRI. However, ZTE-MRI resulted in smaller estimates of bone width and area.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Fuglsig JMCES, Schropp L, Hansen B, et al. Jawbone measurements of edentulous sites related to implant planning using magnetic resonance imaging compared to cone beam computed tomography: An ex vivo study. Clin Oral Implants Res. 2023. PMID: 37985190. doi:10.1111/clr.14211

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。