文献速递口腔修复与种植

预制辅助装置与扫描模式对全牙弓种植数字印模准确性的影响

Effect of prefabricated auxiliary devices and scanning patterns on the accuracy of complete-arch implant digital impressions.
PubMed 文献 · J Dent · 2023-11-21

本研究在无牙上颌模型植入四个平行种植体类似物和四个预制辅助装置(PAD),用口内扫描仪按8种扫描模式(SPA–SPH)分别在有/无PAD条件下扫描,以D2000实验室扫描仪为参考。结果显示扫描模式对PAD组线性准确性和两组扫描时间有显著影响,PAD在所有扫描模式下均提升线性准确性。

要点

  • PAD在所有测试扫描模式下均能提升线性准确性。
  • SPF和SPG在PAD组线性真实度较低(p<0.05)。
  • SPB和SPG在两组中扫描时间均较长。

核心结论

  • 扫描模式对准确性的影响因是否使用PAD而异。
  • 扫描时间可受扫描模式和PAD显著影响。

研究设计与样本

  • 在无牙上颌模型植入四个平行种植体类似物和四个PAD,以D2000牙科实验室扫描仪扫描为参考。
  • 由口内扫描仪(Aoralscan 3,3DShining)按8种扫描模式(SPA–SPH)在有(试验组)或无(对照组)PAD条件下获取测试扫描。
  • SPA为制造商推荐的扫描模式,记录每次扫描时间,相关文件导入检查软件评估。
  • 采用对齐秩变换方差分析、Kruskal-Wallis和Mann-Whitney检验,显著性水平α=0.05。

主要发现

  • 扫描模式显著影响试验组的线性准确性和两组的扫描时间。
  • 试验组中SPF(p<0.05)和SPG(p<0.05)线性真实度较低。
  • 两组中SPB和SPG扫描时间较长。
  • 试验组在所有扫描模式下线性准确性均提升。
  • 角度真实度在SPA(p<0.05)、SPC(p<0.01)和SPH(p<0.01)中提升。

关键数值与推荐

  • 使用PAD时,SPB(p<0.05)、SPF(p<0.05)、SPG(p<0.05)和SPH(p<0.05)扫描时间显著更长。

临床怎么用

  • 日常临床中,选择合适的扫描模式对获得准确数字印模具有重要意义。
  • PAD在所有测试扫描模式下均表现出有效的线性准确性提升。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: This study aimed to evaluate the impact of prefabricated auxiliary devices (PAD) and scanning patterns on the accuracy of complete-arch implant digital impressions. METHODS: An edentulous maxillary model was inserted with four parallel implant analogs and four PAD. The model was scanned with D2000 dental laboratory scanner as the reference scans. Test scans were obtained by 8 different scanning patterns (SP), which including SPA, SPB, SPC, SPD, SPE, SPF, SPG and SPH, with (test group) or without (control group) using the PAD by an intraoral scanner (Aoralscan 3, 3DShining). SPA was the scanning pattern recommended by the manufacturer. Each scanning time was recorded. The related files were imported into inspection software for assessment. Aligned Ranks Transformation ANOVA, Kruskal-Wallis and Mann-Whitney tests were used to evaluate the values. The level of significance was set at α = 0.05. RESULTS: The scanning patterns significantly influenced the linear accuracy in the test group and the scanning time for both groups. Lower linear trueness in the test group was found in SPF (p<0.05) and SPG (p<0.05). Longer scanning time was found in SPB and SPG for both groups. The test group demonstrated linear accuracy enhancement in all the scanning patterns; angular trueness enhancement was seen in SPA (p<0.05), SPC (p<0.01) and SPH (p<0.01). Significant longer scanning time was found in SPB (p<0.05), SPF (p<0.05), SPG (p<0.05) and SPH (p<0.05) when using PAD. CONCLUSION: The scanning patterns impact the accuracy differently depending on the PAD's existence. The scanning time can be significantly influenced by the scanning patterns and the PAD. CLINICAL SIGNIFICANCE: In daily clinical practice, selecting a suitable scanning pattern is significant in achieving accurate digital impressions. The PAD demonstrated effective linear accuracy enhancement in all the scanning patterns tested.

来源:J Dent,查看原文。版权归原作者所有。

引用

  1. Wu HK, Chen G, Wang J, et al. Effect of prefabricated auxiliary devices and scanning patterns on the accuracy of complete-arch implant digital impressions. J Dent. 2023. PMID: 37992957. doi:10.1016/j.jdent.2023.104788

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。