动态导航与自主机器人辅助种植体植入精度的回顾性对比研究
该回顾性研究分析2021年7月至2022年12月部分牙列缺损患者的病历,比较动态计算机辅助种植手术(d-CAIS)与自主机器人计算机辅助种植手术(r-CAIS)的植入精度。
要点
- r-CAIS组角度偏差1.37 ± 0.92°,显著小于d-CAIS组的4.09 ± 1.79°。
- r-CAIS组冠部与根尖全局偏差均显著小于d-CAIS组。
- 两组患者报告的VAS结局无统计学差异。
核心结论
- r-CAIS比d-CAIS技术实现更精确的种植体植入。
- 两组通过VAS评估的总体结果均令人满意。
研究设计与样本
- 回顾性分析2021年7月至2022年12月部分牙列缺损患者的病历。
- 通过锥形束CT比较植入精度,并使用视觉模拟量表记录患者报告结局。
主要发现
- 角度偏差:d-CAIS组4.09 ± 1.79° vs r-CAIS组1.37 ± 0.92°(p < .001)。
- 冠部全局偏差:d-CAIS组1.25 ± 0.54 mm vs r-CAIS组0.68 ± 0.36 mm(p < .001)。
- 根尖全局偏差:d-CAIS组1.39 ± 0.52 mm vs r-CAIS组0.69 ± 0.36 mm(p < .001)。
- 患者报告结局(PROMs)两组间无统计学差异。
关键数值与推荐
- 角度偏差、冠部全局偏差、根尖全局偏差的组间比较均显示p < .001。
- 显著性差异定义为p < .05。
临床怎么用
- 在追求更高种植体植入精度时,可优先考虑r-CAIS方法。
- 两种方法均可获得满意的患者报告结局。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Optimal implant planning and placement allows the prosthesis to be well designed to achieve a satisfactory aesthetic and functional outcome. We aimed to compare deviations between implant planning and placement with the assistance of dynamic computer-assisted implant surgery (d-CAIS) or autonomous robotic computer-assisted implant surgery (r-CAIS) methods in a clinical setting. METHODS: The retrospective analysis of medical records between 2021 July and 2022 December was conducted to compare the implantation accuracy of the d-CAIS and r-CAIS system in partially edentulous patients through cone-beam computed tomography. Patient-reported outcomes (PROs) were recorded using a visual analogue scale (VAS). The Kolmogorov-Smirnov test was used to check the data distribution. Student's t-test or Mann-Whitney U-test was used as appropriate, with a defined significant difference (p < .05). RESULTS: Seventy-seven patients were analysed (124 implants), with 38 patients (62 implants) in the d-CAIS group and 39 patients (62 implants) in the r-CAIS group. The differences between d-CAIS and r-CAIS were 4.09 ± 1.79° versus 1.37 ± 0.92° (p < .001) in angular deviation; 1.25 ± 0.54 versus 0.68 ± 0.36 mm (p < .001) in coronal global deviation; 1.39 ± 0.52 versus 0.69 ± 0.36 mm (p < .001) in apical global deviation; the results of the PROMs showed no statistical difference between the two groups. CONCLUSIONS: r-CAIS allows more accurate implant placement than the d-CAIS technology. And both groups achieved overall satisfactory outcomes via VAS (Chinese Clinical Trial Registry ChiCTR2300072004).
引用
- Zhang S, Cai Q, Chen W, et al. Accuracy of implant placement via dynamic navigation and autonomous robotic computer-assisted implant surgery methods: A retrospective study. Clin Oral Implants Res. 2023. PMID: 38033198. doi:10.1111/clr.14216
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。