虚拟单牙种植体定位的个体间与个体内变异
本前瞻性研究对15例患者基于口内扫描与锥形束CT进行虚拟单牙种植规划,由6名新手和6名专家(口腔外科与修复)完成。发现个体间角度、嵴顶和根尖偏差分别为3.8°、1.11mm和1.54mm,专家偏差低于新手,规划时间与偏差相关。
要点
- 虚拟单牙种植规划存在显著个体间和个体内变异
- 专家规划偏差低于新手,且更长的规划时间仅降低专家偏差
- 口腔外科医生嵴顶偏差低于修复医生,但角度和根尖偏差无差异
核心结论
- 虚拟单牙种植体定位存在显著的个体间和个体内变异,专业水平和投入时间影响偏差。
研究设计与样本
- 前瞻性研究,对15例患者匹配的拔牙前后口内扫描和锥形束CT进行虚拟种植规划,12名检查者(6名新手和6名专家)完成,1个月后重复规划。
主要发现
- 个体间平均角度、嵴顶和根尖偏差分别为3.8±1.94°、1.11±0.55 mm和1.54±0.66 mm;个体内分别为3.28±1.99°、0.78±0.46 mm和1.12±0.61 mm。
- 专家规划偏差显著低于新手;规划时间越长专家偏差越低,新手无此现象。
- 口腔外科医生嵴顶偏差低于修复医生,但角度和根尖偏差无差异;使用修复体设置仅带来微小调整。
临床怎么用
- 临床使用虚拟种植规划软件时需注意操作者间和重复规划间的偏差,建议由经验丰富的医生规划并保证充足时间。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The purpose of this prospective study was to determine the inter- and intraindividual variability in virtual single-tooth implant positioning based on the level of expertise, specialty, total time spent, and the use of a prosthetic tooth setup. MATERIALS AND METHODS: Virtual implant planning was performed on matched pre- and post-extraction intraoral scans (IOS), and cone-beam computed tomography scans of 15 patients. Twelve individual examiners, involving six novices and experts from oral surgery and prosthodontics positioned the implants, first based on anatomical landmarks utilizing only the post-extraction, and second with the use of the pre-extraction IOS as a setup. The time for implant positioning was recorded. After 1 month, all virtual plannings were performed again. The individual implant positions were superimposed to obtain 3D deviations using a software algorithm. RESULTS: An interindividual variability with mean angular, crestal, and apical positional deviations of 3.8 ± 1.94°, 1.11 ± 0.55, and 1.54 ± 0.66 mm, respectively, was found. When assessing intraindividual variability, deviations of 3.28 ± 1.99°, 0.78 ± 0.46, and 1.12 ± 0.61 mm, respectively, were observed. Implants planned by experts exhibited statistically lower deviations compared to those planned by novices. Longer planning times resulted in lower deviations in the experts' group but not in the novices. Oral surgeons demonstrated lower crestal, but not angular and apical deviations than prosthodontists. The use of a setup only led to minor adjustments. CONCLUSIONS: Substantial inter- and intraindividual variability exists during implant positioning utilizing specialized software planning. The level of expertise and the time invested influenced the deviations of the implant position during the planning sequence.
引用
- Raabe C, Biel P, Dulla FA, et al. Inter- and intraindividual variability in virtual single-tooth implant positioning. Clin Oral Implants Res. 2023. PMID: 37966052. doi:10.1111/clr.14203
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。