该研究通过在线问卷调查澳大利亚、新西兰、英国、加拿大、意大利和美国牙科及牙髓协会成员,了解其CBCT培训来源、采集与解读考量、使用情况、首选解读者和牙髓扫描设置偏好。结果显示,牙髓专科组CBCT使用率(90.8%)和工作场所可及性(81.1%)均高于非牙髓牙医组(分别为45.4%和25.9%,p < .001),继续职业教育是最常见培训来源(69.2%)。
要点
- 牙髓专科医生CBCT使用率90.8%,显著高于非牙髓牙医的45.4%。
- 继续职业教育是CBCT培训最常见来源,占69.2%。
- 牙髓CBCT首选小视野(83.6%)和高分辨率(86.6%)设置。
核心结论
- CBCT培训最常通过继续职业教育获得。
- 牙髓专科受访者报告了极高的CBCT使用率和工作场所可及性。
- 在CBCT局限性、合理应用和解读方面存在教育启示。
研究设计与样本
- 研究采用在线问卷调查。
- 调查对象为澳大利亚和新西兰牙科协会成员,以及澳大利亚、英国、加拿大、意大利、新西兰和美国牙髓协会成员。
- 共纳入578名牙髓专科医生或研究生(E组)和185名非牙髓牙医(NE组)的回复。
- 数据分析使用卡方检验、独立样本t检验、Cochran's Q和McNemar检验。
主要发现
- 继续职业教育是CBCT培训最常见来源,占69.2%。
- CBCT采集/解读时考虑的因素包括线束硬化(75.4%)、辐射暴露(61.1%)和患者移动(58.3%)。
- E组CBCT使用率为90.8%,高于NE组的45.4%(p < .001)。
- E组工作场所CBCT可及性为81.1%,高于NE组的25.9%(p < .001)。
- 多数工作场所扫描(83.3%)和外部扫描(60.5%)由受访者本人解读;E组自我解读的可能性显著高于NE组。
关键数值与推荐
- 牙髓CBCT首选设置:小视野(83.6%)和高分辨率(86.6%);NE组选择这些设置的可能性较低。
- E组内部存在一些地域差异。
临床怎么用
- 牙髓专科医生应重视CBCT的继续职业教育,以提升应用和解读能力。
- 临床选择牙髓CBCT设置时可优先考虑小视野和高分辨率。
- 非牙髓牙医的CBCT使用率和可及性较低,可能需要更多培训和支持。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: This study investigated the adoption of cone-beam computed tomography (CBCT) by dentists and endodontists around the world, including their preferences in endodontic CBCT usage. METHODOLOGY: An online questionnaire surveyed dental association members in Australia and New Zealand, and endodontic association members in Australia, Britain, Canada, Italy, New Zealand and the USA, about their CBCT training history, considerations in acquisition/interpretation, access to and usage of CBCT, preferred scan interpreter, and preferred endodontic scan settings. Data were analysed with Chi-squared, independent sample t-tests, Cochran's Q and McNemar's tests. RESULTS: Responses from 578 endodontic specialists or postgraduates (Group E) and 185 non-endodontic dentists (Group NE) were included. Continuing professional education (CPE) was the most common source of CBCT training (69.2%). Factors considered in CBCT acquisition/interpretation included beam hardening (75.4%), radiation exposure (61.1%) and patient movement (58.3%). Group E reported higher CBCT usage (90.8%) than Group NE (45.4%, p < .001) and greater workplace access to CBCT (81.1% vs. 25.9%, p < .001). Scans were interpreted by the respondent in most workplace scans (83.3%) and externally taken scans (60.5%); Group E were significantly more likely to interpret themselves than Group NE. Small field of view (83.6%) and high resolution (86.6%) were most preferred as settings for endodontic CBCTs; Group NE were less likely to choose these settings. There were some geographic variations within Group E. CONCLUSIONS: CBCT training was most commonly acquired via CPE. Endodontic respondents reported very high CBCT usage and access in the workplace. There are educational implications regarding CBCT limitations, appropriate applications and interpretation.