提升引导种植体植入精度:综合荟萃分析评估现有种植体植入方法的准确性
该荟萃分析纳入体外研究,比较计算机辅助种植手术(CAIS)各模式的精度。共纳入5,894项研究,结果显示机器人CAIS和静态CAIS(sCAIS)精度最高且临床可接受,全引导sCAIS结果最可预测,自由手sCAIS精度最低。
要点
- 机器人CAIS和静态CAIS精度最高且临床可接受。
- 全引导sCAIS在静态CAIS中精度最高且最可预测。
- 自由手种植误差最大,动态CAIS除水平根尖偏差外临床安全。
核心结论
- 全引导sCAIS结果最可预测,自由手sCAIS精度最低,机器人CAIS和静态CAIS精度最高且临床可接受。
研究设计与样本
- 纳入比较术后种植体位置与术前计划的体外研究,使用QUIN工具评估偏倚风险并进行漏斗图敏感性分析。
- 于2023年4月18日系统检索MEDLINE(通过PubMed)、EMBASE和Cochrane对照试验中心注册库,无筛选或限制。
- 共纳入5,894项研究。
主要发现
- 机器人和静态CAIS(sCAIS)具有最精确且临床可接受的结果。
- sCAIS按引导水平分组,全引导种植体植入精度最高。
- 增强现实CAIS(AR-based CAIS)除根尖整体偏差外所有结果临床可接受。
- 动态CAIS(dCAIS)除水平根尖偏差外显示临床安全结果。
- 自由手种植体植入误差最大。
临床怎么用
- 全引导sCAIS可提供最可预测的结果,适用于追求高精度的种植植入。
- AR-based和机器人CAIS可能是有前景的替代方案。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: This meta-analysis aimed to determine the accuracy of currently available computer-assisted implant surgery (CAIS) modalities under in vitro conditions and investigate whether these novel techniques can achieve clinically acceptable accuracy. DATA: In vitro studies comparing the postoperative implant position with the preoperative plan were included. Risk of bias was assessed using the Quality Assessment Tool For In Vitro Studies (QUIN Tool) and a sensitivity analysis was conducted using funnel plots. SOURCES: A systematic search was performed on April 18, 2023, using the following three databases: MEDLINE (via PubMed), EMBASE, and Cochrane Central Register of Controlled Trials. No filters or restrictions were applied during the search. RESULTS: A total of 5,894 studies were included following study selection. Robotic- and static CAIS (sCAIS) had the most accurate and clinically acceptable outcomes. sCAIS was further divided according to the guidance level. Among the sCAIS groups, fully guided implant placement had the greatest accuracy. Augmented reality-based CAIS (AR-based CAIS) had clinically acceptable results for all the outcomes except for apical global deviation. Dynamic CAIS (dCAIS) demonstrated clinically safe results, except for horizontal apical deviation. Freehand implant placement was associated with the greatest number of errors. CONCLUSIONS: Fully guided sCAIS demonstrated the most predictable outcomes, whereas freehand sCAIS demonstrated the lowest accuracy. AR-based and robotic CAIS may be promising alternatives. CLINICAL SIGNIFICANCE: To our knowledge, this is the first meta-analysis to evaluate the accuracy of robotic CAIS and investigate the accuracy of various CAIS modalities.
引用
- Takács A, Hardi E, Cavalcante BGN, et al. Advancing accuracy in guided implant placement: A comprehensive meta-analysis: Meta-Analysis evaluation of the accuracy of available implant placement Methods. J Dent. 2023. PMID: 37863173. doi:10.1016/j.jdent.2023.104748
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。