主动与被动动态导航系统不同配准区域在下颌单颗种植中的精度:体外研究
该体外研究将80颗种植体植入40个缺失左或右第一磨牙的树脂下颌模型,比较被动与主动动态导航系统的精度,并评估配准区域的影响。结果显示仅角度偏差在组间有显著差异,配准区域与各组差异均无显著关联。结论认为两种导航系统体外精度相当,下颌单颗后牙缺失区一侧配准可完成双侧后牙单颗种植。
要点
- 被动与主动动态导航系统在体外种植中精度相当。
- 配准区域(左侧或右侧)对导航精度无显著影响。
- 仅角度偏差在组间存在显著差异。
核心结论
- 被动与主动动态导航方法可实现相当的体外精度。
- 下颌单颗后牙缺失区一侧配准可完成双侧后牙单颗种植。
研究设计与样本
- 体外研究,将80颗种植体植入40个树脂下颌模型,缺失左或右第一磨牙。
- 每个模型使用被动或主动动态导航系统,U形管配准装置固定于缺牙区。
主要发现
- 所有种植体角度偏差为1.563 ± 0.977°,入点偏差为0.725 ± 0.268 mm,根尖偏差为0.808 ± 0.284 mm。
- 主动组角度偏差为1.388 ± 1.090°,入点偏差为0.789 ± 0.285 mm,根尖偏差为0.846 ± 0.301 mm。
- 被动组角度偏差为1.739 ± 0.826°,入点偏差为0.661 ± 0.236 mm,根尖偏差为0.769 ± 0.264 mm。
- 仅角度偏差在组间有显著差异,配准区域与各组差异均无显著关联。
临床怎么用
- 被动与主动动态导航系统均可用于下颌单颗后牙种植,精度相当。
- 下颌单颗后牙缺失时,可在一侧配准完成双侧后牙种植。
局限性
- 本研究为体外树脂模型研究,结论需进一步临床研究验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To gauge the relative accuracy of the use of passive and active dynamic navigation systems when placing dental implants, and to determine how registration areas affect the performance of these systems. MATERIALS AND METHODS: Eighty implants were assigned to be placed into 40 total resin mandible models missing either the left or right first molars using either passive or active dynamic navigation system approaches. U-shaped tube registration devices were fixed in the edentulous site for 20 models each on the left or right side. Planned and actual implant positions were superimposed to assess procedural accuracy, and parameters including 3D entry deviation, angular deviation, and 3D apex deviation were evaluated with Mann-Whitney U tests and Wilcoxon signed-rank tests. RESULTS: Respective angular, entry, and apex deviation values of 1.563 ± 0.977°, 0.725 ± 0.268 mm, and 0.808 ± 0.284 mm were calculated for all included implants, with corresponding values of 1.388 ± 1.090°, 0.789 ± 0.285 mm, and 0.846 ± 0.301 mm in the active group and 1.739 ± 0.826°, 0.661 ± 0.236 mm, and 0.769 ± 0.264 mm in the passive group. Only angular deviation differed significantly among groups, and the registration area was not associated with any significant differences among groups. CONCLUSIONS: Passive and active dynamic navigation approaches can achieve comparable in vitro accuracy. Registration on one side of the missing single posterior tooth area in the mandible can complete single-tooth implantation on both sides of the posterior teeth, highlighting the promise of further clinical research focused on this topic.
引用
- Wu BZ, Ma FF, Yan XY, et al. Accuracy of different registration areas using active and passive dynamic navigation systems in dental implant surgery: An in vitro study. Clin Oral Implants Res. 2023. PMID: 37814595. doi:10.1111/clr.14192
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。