种植位点结缔组织移植后组织再血管化的多普勒超声评估
多普勒超声显示两组主要差异在邻面位点,早期灌注与12个月临床及体积结果相关。
要点
- 两组唇面中部的彩色多普勒速度与能量多普勒变化在12个月内无显著差异。
- 隧道技术组在1周时移植物和瓣的早期动态灌注指标更高。
- 早期组织灌注结果与12个月黏膜裂开覆盖和黏膜厚度增加相关。
核心结论
- 多普勒超声可显示结缔组织移植后种植位点的组织灌注变化。
- 冠向复位瓣与隧道技术的主要灌注差异在邻面位点,早期灌注与12个月临床和体积结果相关。
研究设计与样本
- 分别接受冠向复位瓣加结缔组织移植或隧道技术加结缔组织移植。
- 在基线、1周、1个月、6个月和12个月进行超声扫描。
主要发现
- 回归分析显示两组唇面中部彩色多普勒速度和能量多普勒变化在12个月内无显著差异(p > .05)。
- 两组邻面区域彩色多普勒速度和能量多普勒变化差异显著(两者p < .001)。
- 1周时隧道技术组移植物平均血流强度(p = .027)、瓣平均血流强度(p = .024)和瓣平均灌注缓解强度(p = .031)高于冠向复位瓣组。
- 血流强度方向评估显示1周和1个月时结缔组织移植灌注主要从瓣朝向种植体/骨。
- 早期组织灌注结果与12个月平均软组织裂开覆盖和黏膜厚度增加相关。
临床怎么用
- 多普勒超声可用于无创评估种植位点结缔组织移植后的早期血管化。
- 隧道技术可能在早期获得更高的移植物和瓣灌注,尤其需关注邻面位点差异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To assess the Doppler ultrasonographic tissue perfusion at dental implant sites augmented with connective tissue graft (CTG) using coronally advanced flap (CAF) or tunnel technique (TUN). MATERIALS AND METHODS: Twenty-eight patients presenting with isolated healthy peri-implant soft-tissue dehiscence (PSTD) were included in this randomized clinical trial. PSTDs were treated with either CAF + CTG or TUN + CTG. Ultrasound scans were taken at baseline, 1 week, 1 month, 6 months and 12 months. Tissue perfusion at the mid-facial, mesial and distal aspects of the implant sites was assessed by colour Doppler velocity (CDV) and power Doppler imaging (PDI). Early vascularization of the graft and the flap at 1 week and at 1 month were evaluated via dynamic tissue perfusion measurements (DTPMs), including flow intensity (FI), mean perfusion relief intensity (pRI) and mean perfused area (pA). RESULTS: Regression analysis did not reveal significant differences in terms of mid-facial CDV and PDI changes between CAF and TUN over 12 months (p > .05), while significant differences between the two groups were observed at the interproximal areas (p < .001 for both CDV and PDI changes). Higher early DTPMs were observed at the TUN-treated sites in terms of mean FI of the graft (p = .027) and mean FI (p = .024) and pRI of the flap (p = .031) compared with CAF-treated sites at 1 week. Assessment of the FI direction showed that CTG perfusion at 1 week and at 1 month mainly occurred from the flap towards the implant/bone. Early tissue perfusion outcomes were found to be associated with the 12-month mean PSTD coverage and mucosal thickness gain. CONCLUSIONS: Doppler ultrasonography shows tissue perfusion changes occurring at implant sites augmented with CTG. The main differences in tissue perfusion between CAF and TUN were observed at the interproximal sites, with early perfusion associated with clinical and volumetric outcomes at 12 months.
引用
- Tavelli L, Kripfgans OD, Chan HL, et al. Doppler ultrasonographic evaluation of tissue revascularization following connective tissue graft at implant sites. J Clin Periodontol. 2023. PMID: 37861110. doi:10.1111/jcpe.13889
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。