文献速递口腔修复与种植

影像学牙槽骨评估与种植体初期稳定性相关性的系统综述与Meta分析

Radiographic alveolar bone assessment in correlation with primary implant stability: A systematic review and meta-analysis.
PubMed 文献 · Clin Oral Implants Res · 2023-10-15

结果显示牙槽骨条件与ISQ(r=0.60)、IT(r=0.52)及PTV(r=-0.42)显著相关,低骨密度和薄皮质骨可导致低初期稳定性。

要点

  • 牙槽骨密度与皮质骨厚度和种植体初期稳定性显著相关。
  • 低骨密度与薄皮质骨可能提示初期稳定性不足,需调整治疗计划。
  • CBCT/MDCT影像学骨评估可用于种植术前风险预判。

核心结论

  • 牙槽骨条件与种植体初期稳定性显著相关,低骨密度和薄皮质骨可导致低初期稳定性。

研究设计与样本

  • 系统综述与Meta分析,检索PubMed、SCOPUS和Web of Science截至2022年2月的文献。
  • 共分析1171名受试者的3109枚种植体,其中23项研究进入Meta分析。
  • 采用QUIPS工具评估偏倚风险,基于多水平随机效应模型计算平均相关系数。

主要发现

  • 牙槽骨条件与ISQ显著相关(r=0.60;p<.001)。
  • 牙槽骨条件与IT显著相关(r=0.52;p<.001)。
  • 牙槽骨条件与PTV显著相关(r=-0.42;p<.05)。

临床怎么用

  • 种植术前可参考CBCT/MDCT测量的骨密度与皮质骨厚度预判初期稳定性风险。
  • 对低骨密度或薄皮质骨病例,可考虑调整治疗计划或手术方式以避免骨结合不良。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: The radiographic examination of alveolar bone using 3D radiographic examination is essential in dental implant treatment planning. Our study aimed to systematically review and quantitatively analyze the correlation between alveolar bone parameters, specifically bone density and cortical bone thickness, assessed using cone beam computed tomography (CBCT) and/or multidetector computed tomography (MDCT); and primary implant stability (PIS) determined using implant stability quotient (ISQ), Periotest® value (PTV), and insertion torque value (ITV). METHODS: This review was registered in the PROSPERO database (registration number CRD42022307245). An electronic literature search was conducted on the PubMed, SCOPUS, and Web of Science databases for papers published until February 2022. The Quality Assessment in Prognostic Studies (QUIPS) tool was used to assess risk of bias. Meta-analyses were conducted to calculate the estimated average correlation coefficient based on a multilevel random-effects model, followed by subgroup analysis. RESULTS: Twenty-six studies were included in this review, consisting of 17 prospective cohort studies, eight retrospective cohort studies, and one nonrandomized controlled trial. A total of 3109 implants placed in 1171 subjects were analyzed. Twenty-three studies were evaluated using meta-analysis. The alveolar bone condition was significantly correlated with ISQ (r = 0.60; p < .001), IT (r = 0.52; p < .001), and PTV (r = -0.42; p < .05). CONCLUSION: Alveolar bone condition is significantly associated with PIS. Low bone density and thin cortical bone can lead to low PIS; therefore, modification of treatment planning and surgical procedures might be needed to avoid poor osseointegration.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Putra RH, Cooray U, Nurrachman AS, et al. Radiographic alveolar bone assessment in correlation with primary implant stability: A systematic review and meta-analysis. Clin Oral Implants Res. 2023. PMID: 37840388. doi:10.1111/clr.14195

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。