不同开髓洞型设计对下颌磨牙抗折性的有限元分析
本研究采用有限元分析法,评估下颌第一磨牙在传统、保守和超保守(桁架)三种开髓洞型设计及XP-Endo Shaper或TruNatomy两种旋转系统预备后的抗折性。结果显示超保守和保守洞型的应力低于传统洞型,且TruNatomy预备总体应力低于XP-Endo Shaper。
要点
- 超保守开髓洞型产生的von Mises应力最低,传统洞型最高。
- TruNatomy预备在超保守洞型中颈周牙本质应力低于XP-Endo Shaper。
- 传统和保守洞型中,不同旋转系统对应力分布的影响区域不同。
核心结论
- 超保守和保守开髓洞型的应力低于传统洞型。
- TruNatomy根管预备总体应力值低于XP-Endo Shaper。
研究设计与样本
- 研究使用6颗3D打印下颌第一磨牙模拟天然牙,进行传统、保守和超保守(桁架)开髓洞型预备。
- 每组分别用XP-Endo Shaper或TruNatomy旋转锉进行根管预备,随后进行有限元分析。
主要发现
- 传统开髓洞型的von Mises应力值最高,超保守洞型最低。
- 超保守洞型中,TruNatomy预备的颈周牙本质应力低于XP-Endo Shaper。
- 传统和保守洞型中,XP-Endo Shaper组在釉牙骨质界下2 mm内应力较低,TruNatomy组在接下来的3 mm内应力较低。
临床怎么用
- 临床可优先考虑超保守或保守开髓洞型以降低应力。
- 选择TruNatomy旋转系统可能有助于降低根管预备后的应力。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: This study aimed to assess the fracture resistance of mandibular first molars after preparation with 3 different access cavity designs and 2 rotary systems using finite element analysis. METHODS: Six 3-dimensionally printed mandibular first molars simulating natural teeth received traditional, conservative, and ultraconservative (truss) access cavity preparations. The root canals in each group were instrumented with either XP-Endo Shaper (FKG Dentaire, La Chaux-de-Fonds, Switzerland) or TruNatomy (Dentsply Sirona, Ballaigues, Switzerland) rotary files. The models were individually digitized, and micro-computed tomographic scans were transferred to Mimics software (Materialise NV, Leuven, Belgium) to create a geometric model of the tooth. The designed model was exported to 3-matic software (Materialise NV), and STL files were transferred to Geomagic Design X (3D Systems, Rock Hill, SC). Point cloud data were used for surfacing and transferred to ANSYS software (Ansys, Canonsburg, PA). A 200-N superficial force was applied vertically to the buccal cusps and central fossa, and the maximum and minimum equivalent von Mises stress values were calculated and reported. RESULTS: The traditional and ultraconservative access cavity designs yielded the highest and the lowest von Mises stress values, respectively. In the ultraconservative cavity design, the stress values in pericervical dentin were lower in canal preparation with TruNatomy compared with XP-Endo Shaper. In the traditional and conservative cavity designs, stress was lower in the first 2 mm from the cementoenamel junction in the XP-Endo Shaper group and in the next 3 mm in the TruNatomy group. CONCLUSIONS: Stress was lower in the ultraconservative and conservative cavity designs compared with the traditional design. Also, root canal preparation with TruNatomy yielded lower stress values in general compared with XP-Endo Shaper.
引用
- Rahmatian M, Jafari Z, Moghaddam KN, et al. Finite Element Analysis of Fracture Resistance of Mandibular Molars with Different Access Cavity Designs. J Endod. 2023. PMID: 37804945. doi:10.1016/j.joen.2023.09.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。