文献速递牙体牙髓病

六种根管预备系统根管偏移的Micro-CT研究

Exploring the Efficacy of 6 Preparation Systems for Achieving Minimal Root Canal Transportation: A Micro-CT Investigation.
PubMed 文献 · J Endod · 2023-09-16

结果显示偏移受预备系统和根尖三分之一影响(P<.05),Twisted File Adaptive偏移最大,XP-endo Shaper、ProTaper Next和BioRace偏移最小。

要点

  • XP-endo Shaper平均线性偏移最低,Twisted File Adaptive最高。
  • 根尖三分之一偏移最小,冠部三分之一偏移最大。
  • 冠部多向远中内侧偏移,中根尖多向近中外侧偏移。

核心结论

  • XP-endo Shaper平均线性偏移最低,其次为ProTaper Next、BioRace、Reciproc Blue和Reciproc。
  • Twisted File Adaptive系统表现最差。
  • 偏移方向在冠部多朝向根管内侧面,在中部和根尖三分之一多朝向弯曲外侧。

研究设计与样本

  • 预备前后进行Micro-CT扫描,通过13,542个横截面切片比较根管几何中心确定偏移。
  • 使用单变量GLM模型和Tukey真实显著性差异检验比较线性偏移(α=5%)。

主要发现

  • 偏移受预备系统和根管三分之一影响(P<.05),根管本身无显著影响(P>.05)。
  • Twisted File Adaptive偏移最高(P<.05),XP-endo Shaper、ProTaper Next和BioRace偏移最低(P<.05)。
  • Reciproc Blue和Reciproc结果居中(P<.05)。
  • 根尖三分之一偏移最低,冠部三分之一偏移最高(P<.05)。
  • 预备系统与根管三分之一存在显著交互作用(P<.05)。

临床怎么用

  • 在弯曲根管预备中,可优先考虑偏移较小的XP-endo Shaper、ProTaper Next或BioRace系统。
  • 使用Twisted File Adaptive时需注意其较高的根管偏移风险。
  • 预备时应关注冠部偏移较大及中根尖向弯曲外侧偏移的倾向。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: This study aimed to assess the canal transportation with 6 preparation systems. METHODS: Sixty curved mesial roots of mandibular molars were scanned, and their root canals (n = 20 per group) were prepared with XP-endo Shaper, BioRace, ProTaper Next, Twisted File Adaptive, Reciproc, or Reciproc Blue systems. After preparation, a new scan was conducted, and transportation was determined by comparing the geometric center of the canal in 13,542 cross-sectional slices. The transport direction frequencies were recorded, and linear transport were compared using a Univariate GLM model and Tukey honestly significant difference tests (α = 5 %). RESULTS: Transportation was affected by the preparation system and root third (P < .05), with no significant effect observed for the root canal (P > .05). The Twisted File Adaptive had the highest transport (P < .05), and the lowest transports were observed with XP-endo Shaper, ProTaper Next, and BioRace (P < .05). Reciproc Blue and Reciproc showed intermediate results (P < .05). The apical and coronal third exhibited the lowest and highest transportation, respectively (P < .05). A significant interaction was observed between the preparation system and root third (P < .05). In the coronal third, transportation was mostly toward the disto-inside direction, whereas in the middle and apical thirds, transportation was predominantly toward the mesio-outside direction. CONCLUSIONS: XP-endo Shaper had the lowest mean linear transportation followed by the ProTaper Next, BioRace, Reciproc Blue, and Reciproc systems. The Twisted File Adaptive system had the worst performance. The direction of transportation was generally toward the inner aspect of the canal at the coronal third and toward the outer aspect of the curve at the middle and apical thirds.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Belladonna FG, Guimarães TM, Silva EJNL, et al. Exploring the Efficacy of 6 Preparation Systems for Achieving Minimal Root Canal Transportation: A Micro-CT Investigation. J Endod. 2023. PMID: 37717910. doi:10.1016/j.joen.2023.09.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。