高压蒸汽灭菌对3D打印手术导板尺寸变化的影响:一项体外研究
本研究评估3D打印过程本身及后续高压蒸汽灭菌对五种树脂/打印机组合(RPC)尺寸稳定性的影响。结果显示3D打印本身即引起所有RPC显著尺寸变化,两种灭菌循环后多数导板出现轻微但显著的收缩,程度因RPC而异。
要点
- 3D打印过程本身即可引起所有树脂/打印机组合的显著尺寸变化。
- 两种高压蒸汽灭菌循环后多数导板出现轻微但显著的收缩,程度因组合而异。
- 有一种树脂在两种灭菌循环下均未出现尺寸变化。
核心结论
- 大多数导板因3D打印本身及两种高压蒸汽灭菌循环出现轻微但显著的收缩,程度因不同RPC而异。
- 这些变化是否影响种植体植入精度尚待研究。
研究设计与样本
- 每组中5个导板采用循环1(121°C,1 bar,20.5 min)灭菌,另5个采用循环2(134°C,2 bar,5.5 min)灭菌。
- 所有导板在灭菌前(T0)和灭菌后(T1)使用结构光(SL)3D扫描仪扫描。
- 在原始STL文件和T0、T1的SL扫描上沿x、y、z轴进行线性测量。
- 采用Wilcoxon符号秩检验、Kruskal-Wallis检验和线性混合效应模型进行统计分析。
主要发现
- 3D打印与所有RPC的显著尺寸改变相关。
- 循环1灭菌与x方向(1种RPC)、y方向(2种RPC)和z方向(2种RPC)的显著收缩相关。
- 循环2灭菌与x方向(2种RPC)、y方向(1种RPC)和z方向(1种RPC)的显著收缩相关。
- 一种树脂在两种灭菌循环下均未出现任何尺寸变化。
临床怎么用
- 临床使用3D打印手术导板时需考虑打印及高压蒸汽灭菌可能引起的尺寸收缩,不同树脂/打印机组合收缩程度不同。
局限性
- 这些尺寸变化是否影响种植体植入精度尚待研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Surgical guides are frequently used for dental implant placement. The aim of this study was to evaluate the impact of the 3D printing process itself and subsequent steam autoclaving on the dimensional stability of five different resin/printer combinations (RPCs). MATERIALS AND METHODS: Fifty identical surgical guides (10 per group) were produced consisting of five RPCs. Half of the guides (5 per group) were steam autoclaved with cycle 1 (121°C, 1 bar, 20.5 min) and the other half with cycle 2 (134°C, 2 bar, 5.5 min). All guides were scanned with a structured-light (SL) 3D scanner before (T0) and after (T1) autoclaving. Linear measurements along the x-, y-, and z-axes were performed at landmarks on the original STL file and on SL scans at T0 and T1, respectively. Wilcoxon signed-rank test, Kruskal-Wallis test, and linear mixed-effects models were performed, depending on the analysis. RESULTS: Three-dimensional printing was associated with significant dimensional alterations for all RPCs. Steam autoclaving using cycle 1 was associated with significant shrinkage in x- (1 RPC), y- (2 RPCs), and z-direction (2 RPCs), while cycle 2 was also associated with shrinkage in x- (2 RPCs), y- (1 RPC), and z-direction (1 RPC). One resin did not present any dimensional changes independently of the cycle. CONCLUSIONS: The majority of the guides presented minor but significant shrinkage due to 3D printing itself and both steam autoclaving cycles, the extent varied between different RPCs. Whether these changes compromise implant placement accuracy remains to be investigated.
引用
- Hüfner M, David S, Brunello G, et al. Autoclaving-induced dimensional changes of three-dimensional printed surgical guides: An in vitro study. Clin Oral Implants Res. 2023. PMID: 37565539. doi:10.1111/clr.14158
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。