两种镍钛器械预备联合超声激活次氯酸钠对Vertucci II型根管的消毒与成形比较
研究以Vertucci II型下颌磨牙近中根为对象,比较XP-endo Shaper与TruNatomy预备后联合不锈钢或镍钛超声插件激活次氯酸钠的消毒与成形效果。结果显示XP-endo Shaper的细菌减少量显著高于TruNatomy,不锈钢插件在超声激活阶段的额外抗菌效果优于镍钛插件,两组未预备区域无显著差异。
要点
- XP-endo Shaper预备后细菌减少量显著优于TruNatomy。
- 超声激活阶段不锈钢插件的额外抗菌效果优于镍钛插件。
- 两种器械系统预备后未预备区域面积无显著差异。
核心结论
- XP-endo Shaper在Vertucci II型根管中引起的细菌减少量显著高于TruNatomy。
- 超声激活后不锈钢插件的抗菌效果优于镍钛插件。
- 两种器械系统预备后未预备区域无显著差异。
研究设计与样本
- 采用解剖配对micro-CT分析的离体下颌磨牙近中根,Vertucci II型构型。
- 分为2组,每组n=24,分别使用XP-endo Shaper或TruNatomy器械配合次氯酸钠冲洗。
- 补充超声激活使用不锈钢插件(TruNatomy组)或镍钛插件(XP-endo Shaper组)。
- canal污染采用混合细菌培养30天,于预备前(S1)、预备后(S2)、补充措施后(S3)取样。
- 细菌减少量采用实时定量聚合酶链反应评估,预备前后micro-CT扫描评估成形性能。
主要发现
- 两种器械系统预备均显著降低细菌计数(P < .01)。
- 预备后细菌阴性率:TruNatomy 36%,XP-endo Shaper 35%。
- 超声激活后细菌阴性率升至不锈钢插件59%、镍钛插件65%。
- S2定量数据显示XP-endo Shaper的细菌减少量显著高于TruNatomy(P < .05)。
- 超声激活后组内无显著差异(P > .05),可能因不锈钢插件S2至S3的减少量显著高于镍钛插件(P < .01)。
关键数值与推荐
- 细菌计数显著降低的判定标准为P < .01。
- XP-endo Shaper与TruNatomy细菌减少量差异的判定标准为P < .05。
- 不锈钢与镍钛插件S2至S3减少量差异的判定标准为P < .01。
- 未预备区域组间比较无显著差异的判定标准为P > .05。
- 预备后细菌阴性率TruNatomy为36%、XP-endo Shaper为35%;超声激活后分别为59%和65%。
临床怎么用
- 对Vertucci II型根管可优先考虑XP-endo Shaper以获得更好的细菌减少效果。
- 次氯酸钠超声激活时不锈钢插件的额外抗菌效果可能优于镍钛插件。
- 两种器械系统在未预备区域的成形表现相近,选择时可兼顾消毒效果与操作便利。
局限性
- 为离体牙体外研究,结果需临床验证。
- 仅针对下颌磨牙近中根Vertucci II型构型,外推受限。
- 细菌减少采用混合细菌培养与qPCR评估,与临床感染状态存在差异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: This study compared disinfection and shaping after root canal preparation with either XP-endo Shaper or TruNatomy instrument systems, supplemented by ultrasonic activation of sodium hypochlorite (NaOCl) with either stainless-steel (SS) or nickel-titanium (NiTi) inserts. METHODS: Mesial roots from mandibular molars with Vertucci class II configuration were divided into 2 groups (n = 24) based on anatomically paired micro-computed tomography (micro-CT) analyses. Pre and postpreparation micro-CT scans were obtained to evaluate the shaping performance. The canals were contaminated with a mixed bacterial culture for 30 days and then subjected to preparation with either XP-endo Shaper or TruNatomy instruments using NaOCl irrigation. Supplementary ultrasonic activation of NaOCl was conducted using either an SS (TruNatomy group) or NiTi (XP-endo Shaper group) insert. Bacteriological samples were taken from the canals before preparation (S1), after preparation (S2), and after the supplementary approach (S3). Bacterial reduction was evaluated using a quantitative real-time polymerase chain reaction. RESULTS: Preparation with both instrument systems significantly reduced bacterial counts (P < .01). After preparation, 36% (TruNatomy) and 35% (XP-endo Shaper) were negative for bacteria. These values increased to 59% and 65% after ultrasonic activation with the SS and NiTi inserts, respectively. The quantitative data in S2 showed that XP-endo Shaper promoted a significantly higher bacterial reduction than TruNatomy (P < .05). No significant intragroup differences were observed after ultrasonic activation (P > .05), probably because the SS insert promoted a significantly higher S2-to-S3 reduction than the NiTi insert (P < .01). Micro-CT analysis revealed no significant differences in the unprepared areas between the groups (P > .05). CONCLUSIONS: The XP-endo Shaper caused a significantly higher bacterial reduction than TruNatomy in Vertucci class II canals. Better antibacterial results after ultrasonic activation were observed for the SS ultrasonic inserts than for the NiTi inserts.
引用
- Loyola-Fonseca SC, Campello AF, Rodrigues RCV, et al. Disinfection and Shaping of Vertucci Class II Root Canals after Preparation with Two Instrument Systems and Supplementary Ultrasonic Activation of Sodium Hypochlorite. J Endod. 2023. PMID: 37419243. doi:10.1016/j.joen.2023.06.017
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。