Gentlefile、One Curve与Reciproc Blue根管预备后硬组织碎屑及成形性能比较
本实验室研究通过micro-CT比较了Gentlefile、One Curve和Reciproc Blue三种器械预备含峡部弯曲根管后的硬组织碎屑积累和成形性能。结果显示三组在碎屑百分比和未预备面积上无显著差异,但Reciproc Blue去除牙本质更多且根尖偏移更大,One Curve预备时间最短,Gentlefile偏移小但耗时较长。
要点
- 三种器械在碎屑积累和未预备面积上无显著差异。
- Reciproc Blue牙本质去除量和根尖偏移大于Gentlefile。
- One Curve预备时间显著短于Reciproc Blue和Gentlefile。
核心结论
- Gentlefile、One Curve和Reciproc Blue在含峡部弯曲根管中产生的硬组织碎屑和未预备面积相似。
- Gentlefile在牙本质去除和根尖偏移方面表现更优,但预备时间较长。
主要发现
- 三组硬组织碎屑百分比和未预备根管表面积无显著差异(P > .05)。
- Reciproc Blue组体积和表面积增加百分比显著大于Gentlefile组(P < .05)。
- Gentlefile和One Curve组在距根尖3 mm处的偏移显著小于Reciproc Blue组(P < .001)。
- One Curve组预备时间显著短于Reciproc Blue和Gentlefile组(P < .05)。
临床怎么用
- 对于含峡部弯曲根管,三种器械均可获得相似的碎屑清理效果;若需减少牙本质去除和根尖偏移,可优先考虑Gentlefile,但需接受较长预备时间;One Curve在时间效率上更具优势。
局限性
- 本研究为体外实验,样本量有限(每组10颗),且仅评估了特定弯曲度和峡部存在的磨牙近中根,结论外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: This laboratory study aimed to evaluate the accumulated hard tissue debris (AHTD) and shaping performance following root canal instrumentation with a novel stainless steel rotary system (Gentlefile; MedicNRG, Kibbutz Afikim, Israel) compared with two single-file nickel-titanium instruments of different kinematics through micro-computed tomography (micro-CT) analysis. METHODS: Thirty isthmus-containing mesial roots of human mandibular molars with a curvature of 15°-35° were scanned with micro-CT at an isotropic resolution of 12 μm and randomly assigned to three groups (n = 10) according to the instruments used for canal preparation: Gentlefile (GF; #23/.04), One Curve (OC; #25/.06; Micro-Mega, Besancon, France), and Reciproc Blue R25 (RB; #25/.08; VDW, Munich, Germany). The AHTD, unprepared canal surface area, volume changes, surface area changes, and transportation were evaluated by comparing preoperative and postoperative micro-CT images. In addition, the time required for canal preparation was recorded. Data were statistically analyzed using the one-way analysis of variance (ANOVA) test or the Kruskal-Wallis test at a significance level of 5%. RESULTS: No significant differences were observed in the percentage of AHTD or in the unprepared canal surface area between the three groups (P > .05). The RB group demonstrated a significantly greater percentage increase in volume and surface area than the GF group (P < .05). The GF and OC groups showed significantly less transportation at 3 mm from the apex than the RB group (P < .001). The OC group required significantly less time for instrumentation than the RB and GF groups (P < .05). CONCLUSIONS: Instrumentation with GF (#23/.04), OC, and RB yielded similar levels of AHTD and unprepared surface area in isthmus-containing curved canals. GF achieved this with less dentin removal and apical transportation, at the expense of a longer preparation time.
引用
- Chan CW, Romeo VR, Lee A, et al. Accumulated Hard Tissue Debris and Root Canal Shaping Profiles Following Instrumentation with Gentlefile, One Curve, and Reciproc Blue. J Endod. 2023. PMID: 37516238. doi:10.1016/j.joen.2023.07.019
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。