翼外肌附着类型与颞下颌关节盘位置的相关性:基于WAND高清MRI
本研究纳入85例TMD患者共160侧TMJ,采用WAND耦合头颈联合线圈行TMJ高清MRI,分析翼外肌附着类型与关节盘位置的相关性。结果显示翼外肌附着类型与关节盘位置强相关(χ2=28.20,P=0.002,r=0.776),但与盘可复性移位无显著相关。
要点
- TMD患者翼外肌附着类型与关节盘位置存在强相关(r=0.776)。
- 翼外肌附着类型与关节盘可复性移位无显著相关。
- WAND耦合常规线圈高清MRI可评估翼外肌附着类型及盘位置。
核心结论
- TMD患者翼外肌不同附着类型与关节盘位置之间存在相关。
- WAND耦合常规头颈联合线圈TMJ高清扫描可为评估翼外肌附着类型及关节盘位置提供可靠影像学证据。
研究设计与样本
- 收集2019年10月至2022年1月贵州省人民医院口腔颌面外科诊断为TMD的患者85例,共160侧TMJ。
- 男性16例,女性69例,年龄(32.7±14.2)岁(16~80岁)。
- 所有对象行张、闭口斜矢状位及冠状位WAND耦合头颈联合线圈双侧TMJ高清扫描。
- 采用χ2检验和Pearson相关性分析评估翼外肌附着类型与关节盘位置的相关性。
主要发现
- 翼外肌附着类型Ⅰ型51侧[31.9%(51/160)],Ⅱ型77侧[48.1%(77/160)],Ⅲ型32侧[20.0%(32/160)]。
- 翼外肌不同附着类型与关节盘位置存在强相关(χ2=28.20,P=0.002,r=0.776)。
- 不同附着类型翼外肌与关节盘是否可复性移位之间无显著相关(χ2=0.24,P=0.887,r=0.825)。
临床怎么用
- 对TMD患者可采用WAND耦合常规头颈联合线圈行TMJ高清MRI,评估翼外肌附着类型与关节盘位置。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Objective: To explore the correlation between the attachment type of lateral pterygoid muscle (LPM) and the position of temporomandibular joint (TMJ) disc in patients with temporomandibular disorders (TMD) by using wireless amplified magnetic resonance imaging detector (WAND) coupled with conventional head and neck joint coil for high resolution imaging of TMJ. Methods: Eighty-five patients with TMD diagnosed by oral and maxillofacial surgeons of Guizhou Provincial People's Hospital from October 2019 to January 2022 were collected. A total of 160 TMJ were included. There were 16 males and 69 females, aged (32.7±14.2) years. All patients were scanned with open, closed oblique sagittal and coronal WAND coupled head and neck coils with bilateral TMJ. Based on TMJ and LPM high resolution imaging, to explore the correlation between LPM attachment types and the position of TMJ disc in TMD patients, and to evaluate the potential clinical value of LPM attachment types in TMD patients. χ2 test and Pearson correlation analysis were used to evaluate the correlation between LPM attachment type and TMJ disc location. Results: There were three types of LPM attachment: type Ⅰ in 51 cases [31.9% (51/160)], type Ⅱ in 77 cases [48.1% (77/160)] and type Ⅲ in 32 cases [20.0% (32/160)]. There was a significant correlation between the type of LPM attachment and the position of articular disc (χ2=28.20, P=0.002, r=0.776). There was no statistical significance between the type of LPM attachment and the reversible displacement of articular disc (χ2=0.24, P=0.887, r=0.825). Conclusions: There is a correlation between the attachment type of LPM and the position of the disc in TMD patients. WNAD coupled with conventional head and neck joint coil TMJ high resolution scan can provide reliable imaging evidence for TMD patients in evaluating the type of LPM attachment and the location of disc. 目的: 探讨无线整合型MRI信号放大器(wireless amplified MRI detector,WAND)耦合常规头颈联合线圈行颞下颌关节(temporomandibular joint,TMJ)高清成像,评估颞下颌关节紊乱病(temporomandibular disorders,TMD)患者翼外肌附着类型与颞下颌关节盘位置的相关性。 方法: 收集2019年10月至2022年1月经贵州省人民医院口腔颌面外科诊断为TMD的患者85例(共160侧TMJ),其中男性16例,女性69例,年龄(32.7±14.2)岁(16~80岁),所有纳入对象均行张、闭口斜矢状位以及冠状位WAND耦合头颈联合线圈双侧TMJ高清扫描。基于TMJ及翼外肌高清成像,对比分析TMD患者翼外肌附着类型与TMD患者关节盘位置,采用χ2检验和Pearson相关性分析二者的相关性。 结果: 翼外肌附着类型存在3种,Ⅰ型共51侧[31.9%(51/160)],Ⅱ型共77侧[48.1%(77/160)],Ⅲ型共32侧[20.0%(32/160)];TMD患者翼外肌不同附着类型与关节盘位置存在强相关(χ2=28.20,P=0.002,r=0.776);不同附着类型翼外肌与关节盘是否可复性移位之间无显著相关(χ2=0.24,P=0.887,r=0.825)。 结论: TMD患者翼外肌不同附着类型与关节盘位置之间存在相关,WNAD耦合常规头颈联合线圈TMJ高清扫描可为TMD患者在评估翼外肌附着类型及关节盘位置提供可靠影像学证据。.
引用
- Cheng XG, Tian C, Hu R, et al. [Evaluation of the relationship between the attachment type of lateral pterygoid muscle and the position of temporomandibular joint disc in patients with temporomandibular joint disorders based on wireless amplified MRI detector high resolution imaging]. Zhonghua Kou Qiang Yi Xue Za Zhi. 2023. PMID: 37272002. doi:10.3760/cma.j.cn112144-20230418-00161
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。