后牙6mm短种植体单冠修复十年随机对照试验表现
本研究将后牙单牙缺失患者随机分配至6mm短种植体组(TG)或10mm长种植体组(CG),加载10周后行螺丝固位单冠修复,每年随访维护。10年时TG与CG生存率分别为85.7%和97.1%(P=0.072),边缘骨水平稳定且组间无显著差异。结论认为在严格专业维护下,短种植体单冠修复十年生存率略低但无统计学差异,可作为垂直骨量有限时的选择。
要点
- 6mm短种植体十年生存率85.7%,10mm长种植体97.1%,组间无统计学差异(P=0.072)。
- 丢失种植体几乎均位于下颌,且非因种植体周围炎,而是无炎症体征的晚期骨结合丧失。
- 两组边缘骨水平中位数分别为0.13mm和0.08mm,组间无显著差异。
核心结论
- 在严格专业维护下,6mm短种植体单冠修复十年生存率略低于10mm长种植体但无统计学差异,仍可作为垂直骨量有限时的有价值替代方案。
研究设计与样本
- 随机对照试验,初始纳入94例后牙单牙缺失患者,TG和CG各47例,10年时70例(TG 36例、CG 34例)完成再评估。
- 种植体加载10周后行螺丝固位单冠修复,每年随访进行口腔卫生再指导和抛光。
主要发现
- 十年生存率TG为85.7%、CG为97.1%,组间无显著差异(P=0.072)。
- 丢失的种植体除1枚外均位于下颌,丢失原因为无炎症体征的晚期骨结合丧失,且研究期间边缘骨水平实际稳定。
- 边缘骨水平中位数(四分位距)TG为0.13(0.78)mm、CG为0.08(1.2)mm,组间无显著差异。
- 冠种植体比组间差异高度显著,分别为1.06±0.18mm和0.73±0.17mm(P<0.001)。
- 研究期间技术并发症(如螺丝松动或崩瓷)较少。
关键数值与推荐
- 十年生存率:TG 85.7%,CG 97.1%(P=0.072)。
- 边缘骨水平中位数(四分位距):TG 0.13(0.78)mm,CG 0.08(1.2)mm,组间无显著差异。
- 冠种植体比:TG 1.06±0.18mm,CG 0.73±0.17mm(P<0.001)。
临床怎么用
- 后牙单牙缺失且垂直骨量有限时,6mm短种植体单冠修复可作为替代方案,但需严格专业维护和年度随访。
- 下颌短种植体应用时需关注晚期骨结合丧失风险,即使无炎症体征也应长期监测。
局限性
- 10年随访失访率较高,初始94例中仅70例完成再评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The aim of the study was to compare the clinical and radiographic outcomes of short dental implants (6-mm test group, TG) to longer implants (10-mm control group, CG) with single crown restorations after 10 y of loading. Patients requiring single-tooth replacement in the posterior jaws were randomly assigned to TG or CG. Implants were loaded with screw-retained single crowns after a healing period of 10 wk. Follow-up appointments were scheduled yearly and comprised patient-adapted oral hygiene reinstructions and polishing of all teeth and implants. After 10 y, clinical and radiographical parameters were assessed again. Out of initially 94 patients (47 in TG and CG, each), 70 (36 TG and 34 CG) could be reassessed. Survival rates accounted for 85.7% (TG) and 97.1% (CG), without significant intergroup difference (P = 0.072). All but 1 lost implant had been located in the lower jaw. These implants were not lost due to peri-implantitis but due to a late loss of osseointegration without signs of inflammation and with actually stable marginal bone levels (MBLs) over the investigation period. In general, MBLs were stable with medians (interquartile ranges) of 0.13 (0.78) mm and 0.08 (1.2) mm, for TG and CG, without significant intergroup differences. Crown-to-implant ratio showed a highly significant intergroup difference of 1.06 ± 0.18 mm and 0.73 ± 0.17 mm (P < 0.001). Few technical complications (i.e., screw loosening or chipping) were registered during the investigation period. In conclusion, given stringent professional maintenance, short dental implants with single-crown restorations show a slightly worse but statistically not different survival rate after 10 y, especially in the lower jaw, but can still be considered a valuable alternative, especially when vertical bone dimensions are limited (German Clinical Trials Registry: DRKS00006290).
引用
- Sahrmann P, Naenni N, Jung RE, et al. Ten-Year Performance of Posterior 6-mm Implants with Single-Tooth Restorations: A Randomized Controlled Trial. J Dent Res. 2023. PMID: 37387401. doi:10.1177/00220345231170538