文献速递牙体牙髓病

口内扫描验证引导牙髓治疗精度:离体与临床研究

Ex-vivo and in-vivo validation of a novel measuring protocol for guided endodontics.
PubMed 文献 · J Dent · 2023-05-31

本研究通过离体模型和临床患者验证口内扫描(IOS)测量引导牙髓治疗精度的可行性,并与锥形束CT(CBCT)对比。结论认为IOS可用于精度评估,引导牙髓治疗临床精度高。

要点

  • IOS可替代CBCT测量引导牙髓治疗精度,无额外辐射。
  • 临床平均根尖偏差小于0.5 mm,角度偏差小于2°。
  • 规划时建议保留至少1 mm安全边缘以降低根穿孔风险。

核心结论

  • 口内扫描可用于测量引导牙髓治疗的精度。
  • 临床数据显示引导牙髓治疗精度高,平均根尖偏差小于0.5 mm,平均角度偏差小于2°。

研究设计与样本

  • 统计采用多因素方差分析并经Tukey校正,P≤0.05为显著。

主要发现

  • 临床病例平均冠部偏差0.2 mm、根尖偏差0.45 mm、角度偏差1.91°,平均开髓洞长12.5 mm。

关键数值与推荐

  • 临床可接受精度参考:平均根尖偏差小于0.5 mm,平均角度偏差小于2°。
  • 规划安全边缘:建议围绕计划轨迹保留至少1 mm。

临床怎么用

  • 可用口内扫描替代CBCT进行引导牙髓治疗术后精度评估,避免额外辐射。
  • 规划引导牙髓治疗时保留至少1 mm安全边缘以减少根穿孔风险。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To (1) validate the use of a post-operative intraoral scan (IOS) versus Cone Beam Computed Tomography (CBCT), gold standard, on its ability to measure the accuracy of guided endodontics, and (2) present clinical data on the accuracy of guided endodontics. METHODS: Four models, including 10 extracted teeth each, were created. Forty guided access cavities were planned on dentin to simulate pulp canal obliteration (PCO). Two operators performed guided access cavities. A post-operative CBCT and IOS were acquired. The coronal, apical, and angular deviations were measured with CBCT and IOS. Clinical accuracy was measured using an IOS acquired immediately after drilling the access cavity with the aid of a guide. Data analysis was performed using multiway Anova and corrected for simultaneous hypothesis testing according to Tukey. P ≤ 0.05 was considered statistically significant. Descriptive statistics on the clinical accuracy of guided endodontics were performed. RESULTS: Thirty-eight cavities were assessed with a mean length of 13.8 mm. No statistical difference between operators and methods was found for all parameters (P > 0.05). Thirty-three patients were treated with guided endodontics and measured using an IOS. Results show an average coronal, apical, and angular deviation of 0.2 mm, 0.45 mm, and 1.91° respectively. The average length of the access cavities was 12.5 mm. CONCLUSIONS: An IOS can be used to measure the accuracy of guided endodontics. Clinical data showed high accuracy of guided endodontics with a mean apical deviation smaller than 0.5 mm and a mean angular deviation of less than 2°. CLINICAL SIGNIFICANCE: The use of an IOS does not involve additional radiation exposure. A safety margin of at least 1 mm around the planned trajectory should be respected when planning the case to minimize the possibility of root perforation.

来源:J Dent,查看原文。版权归原作者所有。

引用

  1. Torres A, Dierickx M, Coucke W, et al. Ex-vivo and in-vivo validation of a novel measuring protocol for guided endodontics. J Dent. 2023. PMID: 37263407. doi:10.1016/j.jdent.2023.104566

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。