文献速递牙体牙髓病

新型聚氨酯基封闭剂的膨胀体积与膨胀力研究

Volume and Power of Expansion of Novel Polyurethane-based Sealers.
PubMed 文献 · J Endod · 2023-06-03

本研究比较了三种新型聚氨酯基根管封闭剂(PES、ZPES、EPS)与AH Plus及EndoSequence BC的膨胀体积和膨胀力。结果显示聚氨酯基封闭剂的膨胀体积显著高于AH Plus和EndoSequence BC(P < .05),但各组间膨胀力无显著差异(P > .05),且膨胀体积与膨胀力之间无相关性(P > .05)。

要点

  • 聚氨酯基封闭剂膨胀体积显著高于AH Plus和EndoSequence BC。
  • 各组封闭剂之间膨胀力无显著差异。
  • 膨胀体积与膨胀力之间无相关性。

核心结论

  • 聚氨酯基封闭剂膨胀体积显著高于AH Plus和EndoSequence BC,但膨胀力未显著增加。

研究设计与样本

  • 体外研究,使用36个圆柱体(30个塑料刻度圆柱测膨胀体积,6个钢圆柱测膨胀力),每组n=5,测试72小时。

主要发现

  • PES、ZPES和EPS的膨胀体积显著高于AH Plus和EndoSequence BC(P < .05)。
  • 各根管填充材料间的膨胀力无显著差异(P > .05)。
  • 膨胀体积与膨胀力之间无相关性(P > .05)。

临床怎么用

  • 聚氨酯基封闭剂的高膨胀体积可能改善界面适应,但膨胀力未增加,临床意义需进一步研究。

局限性

  • 体外研究,样本量有限,结果需临床验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Shrinkage and lack of interfacial adaptation between endodontic sealers and root canal walls may jeopardize the root canal treatment outcome. This study aimed to evaluate the volume and power of expansion (and the relationship between the two) of three novel root canal sealers (polyurethane expandable sealer [PES], zeolite + PES [ZPES], and elastomeric polyurethane sealer [EPS]) in comparison with an epoxy-resin based sealer (AH Plus) and a calcium silicate-based sealer (EndoSequence BC). METHODS: This study utilized 36 cylinders (30 plastic graduated cylinders for volume of expansion and 6 steel cylinders for power of expansion) (4 × 10 mm) filled with PES, ZPES, EPS, AH Plus, EndoSequence BC, or water (n = 5/group). The plastic graduated cylinders were inserted inside a customized Linear Swell Meter apparatus to measure the percentage of volumetric expansion. The steel cylinders were placed inside a Linear Swell Meter apparatus mounted onto a universal testing machine to measure the maximum pressure in psi. Specimens were tested for 72 hours for both volume and power of expansion tests. Data were analyzed using Kolmogorov-Smirnov, one-way ANOVA, Post Hoc Tukey, and Pearson correlation tests (P < .05). RESULTS: The volume of expansion of PES, ZPES, and EPS was significantly higher than in AH Plus and EndoSequence BC (P < .05). For the power of expansion, no significant differences were found between the root-filling materials (P > .05). No correlation was seen between the volume and power of expansion (P > .05). CONCLUSION: Although polyurethane-based sealers showed a significantly higher volume of expansion compared to AH Plus and EndoSequence BC, their power of expansion did not increase significantly.

来源:J Endod,查看原文。版权归原作者所有。

引用

  1. Saghiri MA, Vakhnovetsky J, Vakhnovetsky A, et al. Volume and Power of Expansion of Novel Polyurethane-based Sealers. J Endod. 2023. PMID: 37276958. doi:10.1016/j.joen.2023.05.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。