两种配准方法辅助动态导航根尖显微手术的精度与效率体外研究
本研究在三维打印颌骨模型上比较U形管(UT)与牙尖(TC)两种配准方法辅助动态导航根尖显微手术(DN-EMS)的精度与效率。结果显示UT组在平台偏差、末端偏差、角度偏差及切除角度上显著更优(P < .05),配准效率也显著更高(P < .05),但切除长度偏差和截骨体积两组无显著差异。结论认为UT配准更精准高效但需额外装置,TC可作为特定临床任务的替代选择。
要点
- UT配准在平台偏差、末端偏差、角度偏差及切除角度上显著优于TC配准。
- UT配准效率显著高于TC配准,但需额外配准装置。
- 两组切除长度偏差和截骨体积无显著差异。
核心结论
- 基于UT配准的DN-EMS比TC方法更精准高效,但需额外配准装置,TC在特定临床任务中可作为合理替代。
研究设计与样本
- 体外研究,使用三维打印颌骨模型包含40颗牙,分为UT组和TC组各20颗,行动态导航辅助根尖显微手术。
主要发现
- UT组在平均平台偏差、末端偏差、角度偏差和切除角度上显著更优(P < .05)。
- UT组配准效率显著高于TC组(P < .05)。
- 切除长度偏差和截骨体积两组间无显著差异。
关键数值与推荐
- 精度评价指标包括平台偏差、末端偏差、角度偏差、切除角度和切除长度偏差。
- 配准效率定义为完成配准程序所需时间。
- 截骨体积通过Mimics 21.0计算。
- 统计显著性设定为P < .05。
临床怎么用
- 临床行DN-EMS时可优先考虑UT配准以提高精度和效率,但需准备额外配准装置。
- 在特定临床任务中,TC配准可作为UT的合理替代方案。
局限性
- 研究为基于三维打印颌骨模型的体外模拟比较,结论需临床验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: This study aimed to compare the accuracy and efficiency of dynamic navigation-assisted endodontic microsurgery (DN-EMS) using two different registration methods. METHODS: Three-dimensional-printed jaw models, including 40 teeth, were divided into two groups (n = 20). Cone-beam computed tomography images of all teeth were scanned under the same exposing parameters. An endodontic dynamic navigation system (DHC-ENDO1) was used to plan the drilling paths. Dynamic navigation-assisted endodontic microsurgery (DN-EMS) was performed using either U-shaped tube (UT) or tooth cusp (TC) registration method. The accuracy was determined by platform deviation, end deviation, angular deviation, resection angle, and resection length deviation. The registration efficiency was defined as the time required to complete the registration procedure. Osteotomy volume of each resection was calculated by Mimics 21.0. Statistical analyses were performed using IBM SPSS Statistics 24.0. Comparisons between groups were performed using the independent sample t test or Mann-Whitney U test. P < .05 was adopted as significant difference. RESULTS: The UT group was significantly more accurate in terms of mean platform deviation, end deviation, angular deviation, and resection angle (P < .05). Resection length deviation did not differ significantly between the registration groups. The UT group was significantly more efficient than the TC group (P < .05). No significant differences were found in the osteotomy volumes between the two groups. CONCLUSIONS: In the model-based surgical simulation comparison, DN-EMS based on UT registration is more accurate and efficient than the TC method but requires an additional registration device. TC technique may be a reasonable alternative to UT registration in certain clinical tasks.
引用
- Wang Z, Chen C, Qin L, et al. Accuracy and Efficiency of Endodontic Microsurgery Assisted by Dynamic Navigation Based on Two Different Registration Methods: An In Vitro Study. J Endod. 2023. PMID: 37356477. doi:10.1016/j.joen.2023.06.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。