文献速递口腔修复与种植

基准标记数量与分布对机器人引导无牙下颌种植精度的影响:体外研究

Effect of the number and distribution of fiducial markers on the accuracy of robot-guided implant surgery in edentulous mandibular arches: An in vitro study.
PubMed 文献 · J Dent · 2023-04-25

该体外研究在无牙下颌模型上评估机器人引导种植时不同数量(3、4、5、6个)和分布(分散或集中)基准标记的配准精度。结果显示植入6个标记时平台偏差(0.53±0.19 mm)和根尖偏差(0.59±0.2 mm)最优,但角度偏差在各标记数量间无显著差异,分散与集中分布间种植位置精度也无显著差异。结论为植入6个基准标记可显著提高种植精度。

要点

  • 植入6个基准标记时平台偏差0.53±0.19 mm、根尖偏差0.59±0.2 mm,为最优精度。
  • 不同数量基准标记间的角度偏差无显著差异。
  • 分散与集中分布的基准标记间种植位置精度无显著差异。

核心结论

  • 在机器人引导无牙下颌种植中,植入6个基准标记可显著提高种植精度。

研究设计与样本

  • 体外研究:在无牙下颌模型上数字规划并机器人引导植入4颗种植体,使用不同数量(3、4、5、6个)和分布(分散或集中)的基准标记进行配准。

主要发现

  • 植入6个基准标记时平台偏差为0.53±0.19 mm,根尖偏差为0.59±0.2 mm,种植位置精度最优。
  • 不同数量基准标记间的角度偏差无显著差异。
  • 分散与集中分布的基准标记间种植位置精度无显著差异。

临床怎么用

  • 本体外研究结果可为临床医生确定基准标记的最佳放置提供参考,并促进机器人引导系统在无牙患者种植中的应用。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Robot-guided implant placement based on the screw marker-assisted registration technique has been applied in dentistry. This study aimed to identify the optimal number and distribution of fiducial markers for robot-guided implant placement in edentulous mandibular phantoms. METHODS: Four implants were digitally planned and placed in edentulous mandibular phantoms under robotic guidance. Different numbers of fiducial markers (3, 4, 5, or 6) and distribution patterns (dispersed or localized) were used to register the robotic system. Platform, apex, and angular deviations were measured between the planned and actual implant positions using different numbers and distributions of fiducial markers. RESULTS: Inserting six fiducial markers resulted in optimal implant position accuracy at the platform (0.53 ± 0.19 mm) and apex (0.59 ± 0.2 mm) deviations. However, the angular deviation did not differ significantly between different numbers of fiducial markers. Furthermore, the implant position accuracy did not differ significantly between the dispersed and localized distributions of fiducial markers. CONCLUSION: In robot-guided implant placement for edentulous mandibular arches, the insertion of six fiducial markers significantly increases the implant placement accuracy. CLINICAL SIGNIFICANCE: The findings of this in vitro study may serve as a reference for clinicians to determine the optimal placement of fiducial markers and to facilitate the clinical application of robot-guided systems for implant placement in edentulous patients. Further clinical studies are necessary to confirm these findings.

来源:J Dent,查看原文。版权归原作者所有。

引用

  1. Zhao Y, Liao Y, Wu X, et al. Effect of the number and distribution of fiducial markers on the accuracy of robot-guided implant surgery in edentulous mandibular arches: An in vitro study. J Dent. 2023. PMID: 37105431. doi:10.1016/j.jdent.2023.104529

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。