3D打印新型钛种植体与传统钛种植体序贯骨结合比较
本研究在8只Beagle犬下颌骨中植入两种基于3D打印的新型钛种植体及两种商用对照种植体,观察2周和6周愈合期。组织形态计量学显示对照组新矿化骨BIC百分比在2周和6周均更高(p < .05),而micro-CT分析显示两种试验种植体BIC显著高于对照组(p < .001)。结论认为3D打印新型钛种植体系统获得的骨结合值足够且令人满意,对照组新矿化骨百分比较高可由完全不同的三维表面积解释。
要点
- 组织形态计量学显示对照组新矿化骨BIC百分比在2周和6周均高于试验种植体(p < .05)。
- micro-CT分析显示两种试验种植体BIC显著高于对照组(p < .001)。
- 试验种植体总表面积约为对照种植体的两倍。
核心结论
- 基于3D打印的新型钛种植体系统获得的骨结合值足够且令人满意。
- 对照组新矿化骨百分比较高可由完全不同的三维表面积解释。
研究设计与样本
- 在8只Beagle犬下颌骨中测试两种基于3D打印的新型钛种植体,并使用两种不同商用钛种植体作为对照。
- 种植体分阶段设置2周和6周愈合期。
- 主要结局变量为非脱钙组织切片中的骨-种植体接触(BIC)和micro-CT分析。
主要发现
- 组织形态计量学显示所有种植体周围组织比例相似,但对照组新矿化骨BIC百分比在2周和6周均高于试验种植体(p < .05)。
- micro-CT分析显示从2周到6周骨体积和BIC增加。
- 与组织形态计量学相反,micro-CT数据的BIC评估显示两种试验种植体BIC显著高于对照组(p < .001)。
- 试验种植体总表面积约为对照种植体的两倍。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To evaluate the sequential osseointegration of a novel titanium implant system based on a 3D printing technology in comparison with conventional titanium implants. MATERIAL AND METHODS: Two novel titanium implants based on 3D printing were tested in the mandible of eight Beagle dogs. As a control, two different commercially available titanium implants were used. The implants were staged to accommodate healing periods of 2 and 6 weeks. The primary outcome variable was bone-to-implant contact (BIC) in non-decalcified tissue sections and micro-CT analysis. RESULTS: Histomorphometrically, the proportions of tissues adjacent to the implant surfaces were similar for all implants, whereas the BIC percentage of new mineralized bone was greater for the control implants after both 2 and 6 weeks (p < .05). Micro-CT analysis revealed increasing osseous volume and BIC from 2 to 6 weeks. In contrast to the histomorphometry, the BIC evaluation with the micro-CT data revealed a significantly higher BIC for the two test implants compared with controls (p < .001). The analysis of the total implant surface area disclosed a value that was approximately double as high for the test compared to the control implants. CONCLUSIONS: The novel titanium implant system based on 3D printing yielded values for osseointegration that were adequate and satisfactory. The higher percentage of new mineralized bone in the control implants is explained by the fact of a completely different three-dimensional surface area.
引用
- Lang NP, Imber JC, Lang KN, et al. Sequential osseointegration of a novel implant system based on 3D printing in comparison with conventional titanium implants. Clin Oral Implants Res. 2023. PMID: 37084177. doi:10.1111/clr.14072
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。