MRI与CBCT检测垂直根折的敏感性与特异性比较:以microCT为参考标准
本研究以120颗离体人牙根为样本,行根管治疗后机械性诱导部分样本产生垂直根折(VRF),由3名认证牙髓专科医生分别判读MRI与CBCT轴位图像,以microCT为参考标准比较诊断效能。结果显示MRI敏感性0.66、特异性0.72,CBCT敏感性0.58、特异性0.87,两者曲线下面积分别为0.74与0.75,敏感性与特异性均无显著差异。
要点
- MRI检测VRF的敏感性为0.66(95%CI 0.53-0.78),特异性为0.72(95%CI 0.58-0.83)。
- CBCT检测VRF的敏感性为0.58(95%CI 0.45-0.70),特异性为0.87(95%CI 0.75-0.95)。
- MRI与CBCT的AUC分别为0.74与0.75,两者敏感性与特异性均无显著差异。
核心结论
- MRI与CBCT检测垂直根折的敏感性和特异性均无显著差异,尽管MRI尚处于早期发展阶段。
研究设计与样本
- 共120颗离体人牙根行根管治疗后机械性诱导部分样本产生垂直根折,样本接受MRI、CBCT和microCT成像,由3名认证牙髓专科医生判读轴位图像。
主要发现
- MRI敏感性0.66(95%CI 0.53-0.78)vs CBCT敏感性0.58(95%CI 0.45-0.70)。
- MRI特异性0.72(95%CI 0.58-0.83)vs CBCT特异性0.87(95%CI 0.75-0.95)。
- MRI的AUC为0.74(95%CI 0.65-0.83),CBCT的AUC为0.75(95%CI 0.66-0.84)。
- MRI评分者内信度0.29-0.48,CBCT评分者内信度0.30-0.44;MRI评分者间信度0.37,CBCT评分者间信度0.49。
关键数值与推荐
- MRI敏感性0.66(95%CI 0.53-0.78),特异性0.72(95%CI 0.58-0.83)。
- CBCT敏感性0.58(95%CI 0.45-0.70),特异性0.87(95%CI 0.75-0.95)。
- MRI的AUC 0.74(95%CI 0.65-0.83),CBCT的AUC 0.75(95%CI 0.66-0.84)。
临床怎么用
- 原文未报告临床应用建议。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Vertical root fracture (VRF) in root-canal-treated teeth frequently results in tooth loss, partly because VRFs are difficult to diagnose and when detected the fracture is often beyond the point of preservation with surgical intervention. Nonionizing magnetic resonance imaging (MRI) has demonstrated the ability to detect small VRFs, but it is unknown how its diagnostic capabilities compare with the current imaging standard for VRF detection, cone-beam computed tomography (CBCT). This investigation aimed to compare the sensitivity and specificity between MRI and CBCT for detecting VRF, using micro-computed tomography (microCT) as a reference. METHODS: A total of 120 extracted human tooth roots were root canal treated using common techniques, and VRFs were mechanically induced in a proportion. Samples were imaged using MRI, CBCT, and microCT. Axial MRI and CBCT images were examined by 3 board-certified endodontists, who evaluated VRF status (yes/no) and gave a confidence assessment for that decision, from which a receiver operating characteristic curve was generated. Intra- and inter-rater reliability were calculated, sensitivity and specificity, and area under the curve. RESULTS: Intra-rater reliability was 0.29-0.48 for MRI and 0.30-0.44 for CBCT. Inter-rater reliability for MRI was 0.37 and for CBCT 0.49. Sensitivity was 0.66 (95% confidence interval [CI], 0.53-0.78) and 0.58 (95% CI, 0.45-0.70), and specificity 0.72 (95% CI, 0.58-0.83) and 0.87 (95% CI, 0.75-0.95) for MRI and CBCT, respectively. Area under the curve was 0.74 (95% CI, 0.65-0.83) for MRI and 0.75 (95% CI, 0.66-0.84) for CBCT. CONCLUSIONS: There was no significant difference in sensitivity or specificity between MRI and CBCT in detecting VRF, despite the early-stage development of MRI.
引用
- Groenke BR, Idiyatullin D, Gaalaas L, et al. Sensitivity and Specificity of MRI versus CBCT to Detect Vertical Root Fractures Using MicroCT as a Reference Standard. J Endod. 2023. PMID: 36972896. doi:10.1016/j.joen.2023.03.011
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。