新型增强现实引导牙髓治疗:一项体外研究

Novel method for augmented reality guided endodontics: An in vitro study.
PubMed 文献 · J Dent · 2023-03-09

本研究在3D打印颌骨模型上评估新型无标记增强现实(AR)系统引导开髓洞型预备的准确性。两名不同经验术者共预备90个开髓洞型,前牙和前磨牙入点平均偏差0.51 mm、根尖点0.77 mm、角度偏差8.5°、表面重叠57%;磨牙入点平均偏差0.63 mm、表面重叠82%。结论认为AR作为数字引导用于牙髓开髓显示出有前景的结果,可能具有临床潜力,但需进一步开发和体内验证。

要点

  • 前牙和前磨牙入点平均偏差0.51 mm,根尖点0.77 mm。
  • 前牙和前磨牙角度偏差8.5°,表面重叠57%。
  • 磨牙入点平均偏差0.63 mm,表面重叠82%。

核心结论

  • AR作为数字引导用于不同牙齿的牙髓开髓洞型预备显示出有前景的结果,可能具有临床潜力。
  • 在体内验证之前,可能还需要进一步开发和研究。

研究设计与样本

  • 体外研究,在3D打印颌骨模型(Objet Connex 350, Stratasys)上由两名不同牙髓经验水平的术者通过新型无标记AR系统进行虚拟规划引导的开髓洞型预备。
  • 共预备90个开髓洞型,深度达牙内4 mm。
  • 术后拍摄高分辨率CBCT(NewTom VGI Evo, Cefla)并注册至术前模型,使用3D医学软件(3-Matic 15.0, materialise)数字化重建开髓洞型。

主要发现

  • 前牙和前磨牙入点平均偏差0.51 mm,根尖点平均偏差0.77 mm,平均角度偏差8.5°,平均表面重叠57%。
  • 磨牙入点平均偏差0.63 mm,平均表面重叠82%。

临床怎么用

  • AR可作为牙髓开髓洞型预备的数字引导方法,在不同牙齿上显示出有前景的准确性结果。
  • 在临床使用前可能还需要进一步开发和体内验证。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: The aim of this study is to evaluate the accuracy in endodontics of a novel augmented reality (AR) method for guided access cavity preparation in 3D-printed jaws. METHODS: Two operators with different levels of experience in endodontics performed pre-planned virtually guided access cavities through a novel markerless AR system on three sets of 3D-printed jaw models (Objet Connex 350, Stratasys) mounted on a phantom. After the treatment, a post-operative high-resolution CBCT scan (NewTom VGI Evo, Cefla) was taken for each model and registered to the pre-operative model. All the access cavities were then digitally reconstructed by filling the cavity area using 3D medical software (3-Matic 15.0, materialize). For the anterior teeth and the premolars, the deviation at the coronal and apical entry points as well as the angular deviation of the access cavity were compared to the virtual plan. For the molars, the deviation at the coronal entry point was compared to the virtual plan. Additionally, the surface area of all access cavities at the entry point was measured and compared to the virtual plan. Descriptive statistics for each parameter were performed. A 95% confidence interval was calculated. RESULTS: A total of 90 access cavities were drilled up to a depth of 4 mm inside the tooth. The mean deviation in the frontal teeth and in the premolars at the entry point was 0.51 mm and 0.77 mm at the apical point, with a mean angular deviation of 8.5° and a mean surface overlap of 57%. The mean deviation for the molars at the entry point was 0.63 mm, with a mean surface overlap of 82%. CONCLUSION: The use of AR as a digital guide for endodontic access cavity drilling on different teeth showed promising results and might have potential for clinical use. However, further development and research might be needed before in vivo validation.

来源:J Dent,查看原文。版权归原作者所有。