文献速递牙体牙髓病

口内扫描三维模型检测咬合面龋的验证研究

Occlusal caries detection on 3D models obtained with an intraoral scanner. A validation study.
PubMed 文献 · J Dent · 2023-02-28

结果显示两种方法在多数指标上无显著差异,仅内层釉质龋的敏感度存在差异。

要点

  • 三维模型屏幕评估与临床视觉检查诊断咬合面龋的效能相似。
  • 仅内层釉质龋的敏感度在两种方法间存在显著差异。
  • 单独使用牙齿色彩与补充荧光对三维模型评估无差异。

核心结论

  • 使用牙齿色彩或荧光的三维数字模型屏幕视觉评估,在检测和分类恒牙咬合面龋时表现出与临床视觉检查相似的诊断效能。

主要发现

  • 评估方法的准确率(ACC)在初期龋损为0.59-0.79,在中度至广泛龋损为0.77-0.99。
  • 除内层釉质龋对应的敏感度(SE)值外,临床视觉检查与屏幕评估之间未观察到显著差异。
  • 单独使用牙齿色彩与补充荧光的三维模型评估在所有评估的诊断指标上均未发现差异。

临床怎么用

  • 三维口内扫描可作为患者筛查的一部分,辅助检测和分类咬合面龋,并可能用于临床和研究目的的远程龋评估。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To evaluate the diagnostic performance of visual caries assessment on 3D dental models obtained using an intraoral scanner and to compare it with the performance of the clinical visual inspection. METHODS: Fifty-three permanent posterior teeth scheduled for extraction were randomly selected and included in this study. One to three independent examination sites on the occlusal surface of each tooth were clinically inspected using International Caries Detection and Assessment System (ICDAS) criteria. Afterwards, the examined teeth were scanned intraorally with a 3D intraoral scanner (TRIOS 4, 3Shape TRIOS A/S, Copenhagen, Denmark) using white and blue-violet light (415 nm wavelength) to capture the colour and fluorescence signal from the tissues. Six months after the clinical examination, the same examiner conducted the on-screen assessment of the obtained 3D digital dental models at the selected examination sites using modified ICDAS criteria. Both tooth colour and fluorescence texture with high resolution were assessed. Lastly, an independent examiner conducted the histological examination of all teeth after extraction. Using histology as the reference test, Sensitivity (SE), Specificity (SP), Accuracy (ACC), area under the Receiver Operating Characteristic (ROC) curve, and Spearman's correlation coefficient were calculated for the clinical and on-screen ICDAS assessments. RESULTS: The ACC values of the evaluated methods varied between 0.59-0.79 for initial caries lesions and 0.77-0.99 for moderate-extensive caries lesions. Apart from SE values corresponding to caries in the inner half of enamel, no significant difference was observed between clinical visual inspection and on-screen assessment. In addition, no difference was found in the assessment of 3D models with tooth colour alone or supplemented with fluorescence for all the evaluated diagnostic measures. CONCLUSIONS: On-screen visual assessment of 3D digital dental models with tooth colour or fluorescence showed a similar diagnostic performance to the clinical visual inspection when detecting and classifying occlusal caries lesions on permanent teeth. CLINICAL SIGNIFICANCE: 3D intraoral scanning can aid the detection and classification of occlusal caries as part of patient screening and can potentially be used in remote caries assessment for clinical and research purposes.

来源:J Dent,查看原文。版权归原作者所有。

引用

  1. Ntovas P, Michou S, Benetti AR, et al. Occlusal caries detection on 3D models obtained with an intraoral scanner. A validation study. J Dent. 2023. PMID: 36858167. doi:10.1016/j.jdent.2023.104457

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。