动态导航下穿龈与传统翻瓣颧种植体植入的随机临床研究
一项随机对照试验纳入20例无牙上颌患者,比较动态导航下穿龈入路(10例)与传统翻瓣入路(10例)植入颧种植体的精度。穿龈组1例未实现骨结合,其余种植体均骨结合;两组在种植体根尖与入点位置精度上差异有统计学意义(p<0.01)。穿龈组与翻瓣组分别有1例和2例发生Schneiderian膜穿孔,结论认为穿龈入路安全性和精度令人满意。
要点
- 动态导航下穿龈植入颧种植体可获得满意的安全性和精度。
- 两组种植体位置精度在根尖和入点测量上差异有统计学意义(p<0.01)。
- 穿龈组1例、翻瓣组2例发生Schneiderian膜穿孔。
核心结论
- 动态导航引导下穿龈植入颧种植体提供了令人满意的安全性和精度。
研究设计与样本
- 随机对照试验纳入20例患者,随机分为穿龈组(第1组,n=10)和传统组(第2组,n=10),每例在局部麻醉下由动态导航系统引导植入左右各一枚颧种植体,两组手术步骤相同,仅穿龈组不翻瓣。
主要发现
- 除穿龈组1例外,所有种植体均实现骨结合。
- 穿龈组与传统组在颧种植体根尖和入点位置的精度上差异有统计学意义(p<0.01)。
- 根尖和冠部平均偏差分别为5 mm和3 mm,角度偏差为6°,计划与实际手术位置之间根尖垂直差异为2 mm。
- Schneiderian膜穿孔共3例,穿龈组1例、传统组2例。
临床怎么用
- 该操作可在局部麻醉下进行,具有临床优势。
- 在临床病例中使用动态导航前,必须接受充分培训。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The assessment of the accuracy of flapless placement of zygomatic implants in edentulous maxilla using dynamic navigation. METHODS: A randomized controlled trial was carried out on 20 patients. Patients were randomized into two groups, the flapless (Group 1; n=10) and the conventional (Group 2; n=10). In each case two zygomatic implants were inserted under local anaesthesia, one on the right and one on the left side guided by a dynamic navigation system. The surgical procedure was identical in the two groups except for the reflection of the mucoperiosteal flap which was eliminated in the flapless cases. Postoperative CBCT scans were used to assess the accuracy of the placement of zygomatic implants. RESULTS: Osseointegration was achieved for all the implants, except one case in the flapless group. Statistically significant differences in the accuracy of the position of the zygomatic implants was found between the flapless and the conventional groups, measured at the apex and the entry points of the implants (p < 0.01). The average apical and coronal deviations were 5 mm and 3 mm, respectively; the angular deviation was 6°, and 2 mm vertical apical disparity was detected between the planned and the achieved surgical position. Perforation of the Schneiderian membrane was noted in three cases, one in flapless group and two in the conventional group. CONCLUSIONS: Flapless placement of zygomatic implants guided by dynamic navigation offered satisfactory safety and accuracy. CLINICAL SIGNIFICANCE: This is the first clinical trial to prove the feasibility and accuracy of flapless placement of zygomatic implant with minimal morbidity. The study highlights the innovative reflection of the Schneiderian membrane under guided surgical navigation. The procedure can be performed under local anaesthesia, which offers clinical advantages. Adequate training on the use of dynamic navigation is mandatory before its use in clinical cases.
引用
- Bhalerao A, Marimuthu M, Wahab A, et al. Dynamic navigation for zygomatic implant placement: A randomized clinical study comparing the flapless versus the conventional approach. J Dent. 2023. PMID: 36736529. doi:10.1016/j.jdent.2023.104436
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。