文献速递口腔修复与种植

静态与动态计算机辅助联合用于单牙种植的精度:随机对照试验

Accuracy of implant placement with a combined use of static and dynamic computer-assisted implant surgery in single tooth space: A randomized controlled trial.
PubMed 文献 · Clin Oral Implants Res · 2023-02-24

结果显示四组在平台、根尖及角度偏差上均有显著差异(p < .001),SD组精度显著高于S组、D组和FH组。

要点

  • SD组平台3D偏差0.62±0.50 mm,小于S组1.06±0.67 mm、D组1.02±0.45 mm和FH组1.48±0.68 mm。
  • SD组根尖偏差0.75±0.57 mm,小于S组1.40±0.71 mm、D组1.28±0.50 mm和FH组2.18±0.95 mm。
  • SD组角度偏差1.24±1.41度,小于S组3.18±2.04度、D组3.28±1.57度和FH组7.50±4.06度。

核心结论

  • 联合使用静态与动态CAIS在单牙种植中提供的精度显著高于单独使用静态、单独使用动态及徒手手术。

主要发现

  • 四组间平台、根尖及角度偏差均有显著差异(p < .001);SD组平台偏差0.62±0.50 mm、根尖0.75±0.57 mm、角度1.24±1.41度,均为四组中最小。
  • FH组平台偏差较SD组显著偏向近中(p = .026)和冠方(p = .014),根尖偏差较SD组显著偏向远中(p = .004)和舌侧(p = .002)。

关键数值与推荐

  • 平台3D偏差:SD组0.62±0.50 mm vs S组1.06±0.67 mm vs D组1.02±0.45 mm vs FH组1.48±0.68 mm。
  • 根尖3D偏差:SD组0.75±0.57 mm vs S组1.40±0.71 mm vs D组1.28±0.50 mm vs FH组2.18±0.95 mm。
  • 角度偏差:SD组1.24±1.41度 vs S组3.18±2.04度 vs D组3.28±1.57度 vs FH组7.50±4.06度。

临床怎么用

  • 对于单牙种植,联合使用静态导板与动态导航可较单独使用任一方式或徒手手术获得更高的植入精度。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To compare implant accuracy of combined static and dynamic (SD) computer-assisted implant surgery (CAIS) with static (S), dynamic (D) CAIS, and freehand surgery (FH) for single implant placement. MATERIALS AND METHODS: One hundred and twenty patients were randomized into four groups. Implants were placed using both stereolithographic surgical guide and dynamic navigation in the SD group, stereolithographic surgical guide in S group, dynamic navigation in D group, and conventional freehand in FH group. Analysis of deviation between planned and final implant position, as well as K means analysis was conducted for implant deviation at platform, apex, and angle (primary outcomes) and directional distribution at platform and apex (secondary outcome). RESULTS: Significant differences were found among the four groups (p < .001): The 3D deviation at the platform (mm) of SD, S, D, and FH groups was 0.62 ± 0.50, 1.06 ± 0.67, 1.02 ± 0.45, and 1.48 ± 0.68, respectively, at apex (mm) was 0.75 ± 0.57, 1.40 ± 0.71, 1.28 ± 0.50, and 2.18 ± 0.95, respectively, and angle (degrees) was 1.24 ± 1.41, 3.18 ± 2.04, 3.28 ± 1.57, and 7.50 ± 4.06, respectively. Deviation at the platform of FH group was significantly more toward mesial (p = .026) and coronal (p = .014) direction, while at the apex, toward distal (p = .004) and lingual (p = .002) than SD group. CONCLUSION: The use of combined static and dynamic CAIS provided significantly higher accuracy than the two alone and freehand surgery for single implant placement.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Yotpibulwong T, Arunjaroensuk S, Kaboosaya B, et al. Accuracy of implant placement with a combined use of static and dynamic computer-assisted implant surgery in single tooth space: A randomized controlled trial. Clin Oral Implants Res. 2023. PMID: 36756684. doi:10.1111/clr.14043

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。