文献速递口腔修复与种植

动态导航辅助系统对牙种植体植入精度的影响:随机临床试验

Accuracy of dental implant placement with or without the use of a dynamic navigation assisted system: A randomized clinical trial.
PubMed 文献 · Clin Oral Implants Res · 2023-02-26

一项双臂随机临床试验评估动态计算机辅助种植手术(dCAIS)与徒手(FH)法植入种植体的精度,次要比较患者感知与生活质量。结果显示dCAIS组角度偏差显著低于FH组,线性偏差除根尖垂直向无差异外均显著更低;手术时间延长约14分钟,术后疼痛、镇痛药使用与满意度两组相似。

要点

  • dCAIS组平均角度偏差4.02°(95%CI 2.85-5.19),FH组7.97°(95%CI 5.36-10.58),差异显著(p<.001)。
  • 除根尖垂直向无差异外,dCAIS组线性偏差均显著低于FH组。
  • dCAIS手术时间较FH延长14分钟(95%CI 6.43-21.24;p<.001),患者认为可接受。

核心结论

  • dCAIS系统较常规徒手法显著提高部分无牙颌患者种植体植入精度,但显著延长手术时间,且似乎不改善患者满意度或减轻术后疼痛。

主要发现

  • dCAIS组平均角度偏差4.02°(95%CI 2.85-5.19) vs FH组7.97°(95%CI 5.36-10.58),差异显著(p<.001)。
  • 线性偏差除根尖垂直向无差异外,dCAIS组均显著低于FH组。
  • dCAIS组手术时间较FH组延长14分钟(95%CI 6.43-21.24;p<.001),两组患者均认为手术时间可接受。
  • 术后第一周疼痛与镇痛药消耗两组相似,自报满意度均很高。

关键数值与推荐

  • 角度偏差:dCAIS组4.02°(95%CI 2.85-5.19) vs FH组7.97°(95%CI 5.36-10.58),p<.001。
  • 手术时间:dCAIS组较FH组延长14分钟(95%CI 6.43-21.24;p<.001)。
  • 线性偏差:除根尖垂直向无差异外,dCAIS组显著低于FH组。

临床怎么用

  • dCAIS可提高部分无牙颌患者种植体植入精度,但需考虑手术时间延长约14分钟。
  • dCAIS似乎不改善患者满意度或减轻术后疼痛,临床选择需权衡精度与时间成本。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To assess dental implant placement accuracy with a dynamic computer-assisted implant surgery (dCAIS) system and a freehand approach. Secondarily, to compare the patients' perception and quality of life (QoL) with the two approaches. METHODS: A double-arm randomized clinical trial was conducted. Consecutive partially edentulous patients were randomly allocated to the dCAIS or standard freehand approach groups. Implant placement accuracy was evaluated by overlapping the preoperative and postoperative Cone Beam Computer Tomographs (CBCT) and recording linear deviations at the implant apex and platform (in mm) and angular deviations (in degrees). Questionnaires recorded self-reported satisfaction, pain and QoL during surgery and postoperatively. RESULTS: Thirty patients (22 implants) were enrolled in each group. One patient was lost to follow-up. A significant difference (p < .001) in mean angular deviation was found between the dCAIS (4.02°; 95% CI: 2.85 to 5.19) and the FH (7.97°; 95% CI: 5.36 to 10.58) groups. Linear deviations were significantly lower in the dCAIS group, except for the apex vertical deviation, where no differences were found. Although dCAIS took 14 min longer (95% CI: 6.43 to 21.24; p < .001), patients in both groups considered the surgical time acceptable. Postoperative pain and analgesic consumption during the first postoperative week were similar between groups and self-reported satisfaction was very high. CONCLUSION: dCAIS systems significantly increase the accuracy of implant placement in partially edentulous patients in comparison with the conventional freehand approach. However, they increase the surgical time significantly and do not seem to improve patient satisfaction or reduce postoperative pain.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Jorba-García A, Bara-Casaus JJ, Camps-Font O, et al. Accuracy of dental implant placement with or without the use of a dynamic navigation assisted system: A randomized clinical trial. Clin Oral Implants Res. 2023. PMID: 36794798. doi:10.1111/clr.14050

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。