自主机器人辅助单牙种植的精度:病例系列研究
术后CBCT显示种植体总体冠部偏差均值0.74 mm(95%CI:0.53至0.94 mm),根尖部偏差均值0.73 mm(95%CI:0.53至0.93 mm),角度偏差1.11°(95%CI:0.78至1.44°)。未报告不良手术事件及术后并发症。
要点
- 自主机器人单牙种植的冠部偏差均值0.74 mm(95%CI:0.53至0.94 mm)。
- 根尖部偏差均值0.73 mm(95%CI:0.53至0.93 mm),角度偏差1.11°(95%CI:0.78至1.44°)。
核心结论
- 自主机器人计算机辅助种植手术(r-CAIS)在单牙种植中表现出高精度,归因于角度偏差和轴向误差的控制。
主要发现
- 总体冠部偏差均值0.74 mm(95%CI:0.53至0.94 mm)。
- 总体根尖部偏差均值0.73 mm(95%CI:0.53至0.93 mm)。
- 角度偏差均值1.11°(95%CI:0.78至1.44°)。
- 未报告不良手术事件及术后并发症(即感染和早期种植失败)。
临床怎么用
- 研究结果为自主机器人种植手术系统作为牙种植手术的潜在替代方案提供了重要证据。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: This study aimed to investigate the accuracy of the autonomous robotic computer-assisted implant surgery (r-CAIS) for single-tooth implant placement. METHODS: Patients with a single missing tooth were enrolled for the autonomous robotic implant surgery. The patients underwent a cone-beam computed tomography (CBCT) scan with a positioning marker. Virtual preoperative implant placement and a drilling plan were created before surgery. The robotic system automatically performed the implant osteotomy and placement intraoperatively under the surgeon's supervision. A postoperative CBCT scan was performed to evaluate the deviations between the planned and placed implants. RESULTS: Ten patients with single dental implant placement were enrolled. No adverse surgical events and postoperative complications (i.e., infection and early implant failure) were reported. The autonomous robotic implant surgery exhibited a mean overall coronal deviation of 0.74 mm (95% CI: 0.53 to 0.94 mm), a mean overall apical deviation of 0.73 mm (95% CI: 0.53 to 0.93 mm), and an angular deviation of 1.11° (95% CI: 0.78 to 1.44°), respectively. CONCLUSIONS: The high accuracy of autonomous r-CAIS technology in single-tooth implant placement was attributed to the control of the angular deviation and axial errors. CLINICAL SIGNIFICANCE: The main findings of this study provide significant evidence to support the autonomous robotic implant surgery system as a potential alternative in dental implant surgery.
引用
- Yang S, Chen J, Li A, et al. Accuracy of autonomous robotic surgery for single-tooth implant placement: A case series. J Dent. 2023. PMID: 36781099. doi:10.1016/j.jdent.2023.104451
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。