文献速递口腔修复与种植牙周病

钛种植体电化学去污:体外生物膜模型研究

Electrochemical decontamination of titanium dental implants. An in vitro biofilm model study.
PubMed 文献 · Clin Oral Implants Res · 2023-03-12

本研究采用六种细菌的体外龈下生物膜模型,在钛种植体上施加0.75 V、1.5 V、3 V(阳极极化)及-0.75 V、-1.5 V、-3 V(阴极极化)直流电5分钟,用扫描电镜和qPCR评估生物膜结构与细菌组成。3 V和-3 V处理显著降低总活菌数(p<.05),阴极处理的减少效果优于阳极氧化处理;0.75 V和-0.75 V处理对生物膜无影响。

要点

  • 3 V阳极和-3 V阴极电化学处理均显著降低体外多菌种生物膜总活菌数。
  • Fusobacterium nucleatum是活菌浓度下降最显著的菌种。
  • 0.75 V和-0.75 V处理对生物膜无影响。

核心结论

  • 电化学处理对该体外多菌种龈下生物膜模型具有杀菌作用,且阴极还原处理比阳极氧化处理更有效。

研究设计与样本

  • 体外研究,使用六种细菌模拟龈下口腔生物膜并接种于钛种植体。
  • 采用三电极系统(种植体为工作电极、铂网为对电极、Ag/AgCl为参比电极),施加直流电5分钟。
  • 通过扫描电子显微镜和定量聚合酶链反应评估生物膜结构与细菌组成,并用广义线性模型分析杀菌效果。

主要发现

  • 3 V和-3 V处理显著降低总活菌数(p < .05),分别从3.15 × 10^6降至1.85 × 10^5和2.92 × 10^4活菌/mL。
  • Fusobacterium nucleatum在活菌浓度下降方面受影响最大。
  • 0.75 V和-0.75 V处理对生物膜无影响。

关键数值与推荐

  • 施加直流电参数:0.75 V、1.5 V、3 V(阳极极化)及-0.75 V、-1.5 V、-3 V(阴极极化),持续5分钟。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The objective of this study is to study the effect of electrochemical treatment on biofilms developed on titanium dental implants, using a six-species in vitro model simulating subgingival oral biofilms. MATERIALS AND METHODS: Direct electrical current (DC) of 0.75 V, 1.5 V, and 3 V (anodic polarization, oxidation processes) and of -0.75 V, -1.5 V, and -3 V (cathodic polarization, reduction processes) was applied between the working and the reference electrodes for 5 min on titanium dental implants, which have been previously inoculated with a multispecies biofilm. This electrical application consisted of a three-electrode system where the implant was the working electrode, a platinum mesh was the counter electrode, and an Ag/AgCl electrode was the reference. The effect of the electrical application on the biofilm structure and bacterial composition was evaluated by scanning electron microscopy and quantitative polymerase chain reaction. A generalized linear model was applied to study the bactericidal effect of the proposed treatment. RESULTS: The electrochemical construct at 3 V and -3 V settings significantly reduced total bacterial counts (p < .05) from 3.15 × 106 to 1.85 × 105 and 2.92 × 104 live bacteria/mL, respectively. Fusobacterium nucleatum was the most affected species in terms of reduction in concentration. The 0.75 V and -0.75 V treatments had no effect on the biofilm. CONCLUSION: Electrochemical treatments had a bactericidal effect on this multispecies subgingival in vitro biofilm model, being the reduction more effective than the oxidative treatment.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Virto L, Odeh V, Garcia-Quismondo E, et al. Electrochemical decontamination of titanium dental implants. An in vitro biofilm model study. Clin Oral Implants Res. 2023. PMID: 36847700. doi:10.1111/clr.14055

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。