新型超声尖用于下颌磨牙近中根管峡部充填的微计算机断层扫描评价
本研究利用微计算机断层扫描(μCT)评价两种热塑充填技术——超声垂直加压(UVC)与连续波加压(CWC)——对下颌磨牙近中根管及峡部的充填质量。36颗人下颌磨牙的标本随机分组后充填,结果显示两种技术均未实现根管完全充填(UVC为86.3%,CWC为91.4%),差异有统计学意义(P=0.029),CWC表现更优。
要点
- 两种热塑充填技术均未能完全充填下颌磨牙近中根管及峡部。
- 连续波加压(CWC)的充填率(91.4%)高于超声垂直加压(UVC,86.3%),差异有统计学意义(P=0.029)。
核心结论
- 在本研究条件下,两种热塑充填技术均未完全充填下颌磨牙根管/峡部;连续波加压(CWC)表现更优。
研究设计与样本
- 研究选取36颗人下颌磨牙,预先经μCT扫描筛选出具有形态相似峡部的近中根。
- 样本随机分为UVC组和CWC组,分别采用超声垂直加压和连续波加压技术进行充填。
主要发现
- UVC组根管整体区域(含主根管与峡部)的充填率为86.3%。
- CWC组根管整体区域(含主根管与峡部)的充填率为91.4%,两组差异有统计学意义(P=0.029)。
关键数值与推荐
- 充填率评价基于μCT扫描,由对分组不知情的校准检查者测定整个根管区域(含主根管和峡部)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The obturation quality of the mandibular molar mesial canals and isthmuses with two thermoplastic techniques, ultrasonic vertical condensation (UVC) and continuous wave of condensation (CWC), was evaluated using computed microtomography (μCT). METHODS: Thirty-six human mandibular molars had been previously scanned and analyzed using μCT for mesial roots with morphologically similar isthmuses for this study. Coronal access and confirmation of foraminal patency were performed, and the actual length of the teeth was established using a clinical microscope (40X magnification). The canals were prepared using ProTaper Gold instruments up to #F3, with 2.5% sodium hypochlorite as the irrigant solution, followed by a passive ultrasonic irrigation protocol. The specimens were randomly divided into the UVC and CWC groups based on the obturation technique to be used. Obturation was performed with #F3 gutta-percha cones cemented using AH Plus Jet sealer. The μCT scans were performed after 15 days, and the images were evaluated by a calibrated examiner blinded to the experimental groups to determine the filling rate of the entire canal area, including the main canal and isthmus. Student's t-test was used for statistical analysis; P values ≤0.05 were considered significant. RESULTS: Neither of the thermoplastic obturation techniques achieved complete filling of the canals (86.3% for UVC and 91.4% for CWC), with a statistically significant difference between them (P = .029). CONCLUSIONS: Under the conditions of the study, it can be concluded that none of the techniques completely filled the canal/isthmus of the mandibular molars; however, the CWC exhibited better performance.
引用
- Barreto CDCG, Calefi PHS, Vivacqua-Gomes N, et al. New Ultrasonic Tip for Root Canal Filling of the Mesial Canals of Mandibular Molars with Isthmus: A Laboratory Evaluation Using Computed Microtomography. J Endod. 2023. PMID: 36841383. doi:10.1016/j.joen.2023.02.010
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。