文献速递口腔修复与种植口腔颌面外科

自动与手动动态导航配准在后牙单牙缺失种植中的准确性:回顾性临床分析

Accuracy of automatic and manual dynamic navigation registration techniques for dental implant surgery in posterior sites missing a single tooth: A retrospective clinical analysis.
PubMed 文献 · Clin Oral Implants Res · 2023-02-08

本研究纳入58例后牙单牙缺失的部分无牙颌患者(手动组31枚、自动组27枚种植体),比较手动U形管与自动二合一动态导航配准技术的种植体放置偏差。两组的角度偏差、平台偏差和根尖偏差均无显著差异(p > .05);作者认为两种技术均可获得良好精度,自动二合一配准可减少配准所需时间和术中步骤,但需进一步随访研究。

要点

  • 手动组与自动组的角度、平台和根尖偏差均无显著差异(p > .05)。
  • 总体角度偏差2.54 ± 1.21°,平台和根尖三维偏差分别为0.90 ± 0.46 mm和1.04 ± 0.47 mm。
  • 作者认为自动二合一配准可减少配准时间和术中步骤,需进一步随访研究。

核心结论

  • 手动与自动动态导航配准技术在后牙单牙缺失种植中均可获得良好准确性。
  • 相对于手动U形管配准,二合一自动配准技术可减少完成配准所需的时间和术中步骤。
  • 需要进一步随访研究以扩展这些结果。

研究设计与样本

  • 回顾性临床分析,纳入58例后牙单牙缺失的部分无牙颌患者,共58枚种植体。
  • 手动组31枚种植体,自动组27枚种植体。
  • 评估计划与实际种植体放置之间的偏差。

主要发现

  • 总体队列角度偏差为2.54 ± 1.21°,种植体平台和根尖三维偏差分别为0.90 ± 0.46 mm和1.04 ± 0.47 mm。
  • 手动组与自动组角度偏差分别为2.82 ± 1.17°和2.21 ± 1.19°(p > .05)。
  • 手动组与自动组平台偏差分别为0.89 ± 0.48 mm和0.91 ± 0.45 mm(p > .05)。
  • 手动组与自动组根尖偏差分别为0.99 ± 0.48 mm和1.11 ± 0.46 mm(p > .05)。
  • 两组在平台或根尖水平的颊舌向、近远中向或冠根向绝对偏差及偏差分布均无显著差异(p > .05)。

临床怎么用

  • 作者认为手动和自动动态导航配准技术在后牙单牙缺失种植中均可获得良好准确性。
  • 作者认为二合一自动配准技术可减少配准所需时间和术中步骤。
  • 作者指出需要进一步随访研究以扩展这些结果。

局限性

  • 需要进一步随访研究以扩展这些结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To assess the relative accuracy of manual (U-shaped tube) and automatic (two-in-one) dynamic navigation registration techniques for implant surgery performed in posterior sites missing one tooth. MATERIALS AND METHODS: This study included 58 partially edentulous patients with 58 implants, including 31 and 27 in the manual and automatic groups. Deviations between the planned and actual implant placement were assessed. RESULTS: The angular deviation in the overall study cohort was 2.54 ± 1.21°, while the 3D deviations at the implant platform and apex were 0.90 ± 0.46 mm and 1.04 ± 0.47 mm, respectively. The respective angular deviations in the manual and automatic groups were 2.82 ± 1.17° and 2.21 ± 1.19° (p > .05), while platform deviations were 0.89 ± 0.48 mm and 0.91 ± 0.45 mm (p > .05), and apex deviations were 0.99 ± 0.48 mm and 1.11 ± 0.46 mm (p > .05). No significant differences in absolute buccolingual, mesiodistal, or apicocoronal deviations were detected between these groups at either level (p > .05) nor were did deviation distributions differ in the buccolingual, mesiodistal, or apicocoronal directions at the platform or apex levels (p > .05). CONCLUSIONS: Manual and automatic dynamic navigation registration techniques can achieve excellent accuracy when placing implants in posterior sites missing a single tooth. The two-in-one automatic registration technique can reduce the amount of time and intraoperative steps necessary to complete the registration process relative to the manual U-shaped tube registration technique. Further follow-up studies are necessary to expand on these results.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Wu BZ, Xue F, Ma Y, et al. Accuracy of automatic and manual dynamic navigation registration techniques for dental implant surgery in posterior sites missing a single tooth: A retrospective clinical analysis. Clin Oral Implants Res. 2023. PMID: 36691811. doi:10.1111/clr.14034

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。