PubMed 文献 · Clin Oral Implants Res · 2023-02-05

本研究纳入20例远中游离端缺失、计划行种植支持式固定修复的患者,比较两种颌间记录方法:试验组在颌间记录帽上放置聚乙烯基硅氧烷(PVS),对照组在愈合基台上放置PVS。结果显示试验方法检测口内咬合接触的敏感性更高(p=.002),但阳性预测值相似(p=.10);结论认为该新型颌间记录方法更准确,可减少咬合调整。

要点

  • 纳入20例远中游离端缺失患者,比较颌间记录帽PVS法与愈合基台PVS法。
  • 试验法检测口内咬合接触敏感性高于对照法(p=.002),阳性预测值相似(p=.10)。
  • 试验组咬合调整高度显著低于对照组(p=.03),调整前咬合接触评分更高(p=.006)。

核心结论

  • 新型颌间记录方法用于种植支持式固定修复体更准确,可减少咬合调整。

研究设计与样本

  • 随机临床试验,纳入20例远中游离端两个或以上相邻牙缺失、计划行种植支持式固定修复的患者。
  • 两种颌间记录方法:试验组在颌间记录帽上放置聚乙烯基硅氧烷(PVS),对照组在愈合基台上放置PVS。

主要发现

  • 试验方法检测口内咬合接触的敏感性高于对照方法(p=.002),阳性预测值相似(p=.10)。
  • 试验组调整前咬合接触评分高于对照组(p=.006)。
  • 两组咬合调整体积和时间相似。

临床怎么用

  • 作者认为该新型颌间记录方法更准确,可减少种植支持式固定修复体的咬合调整。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To investigate the effect of a novel interocclusal recording method on the occlusal accuracy of implant-supported fixed prostheses for partially dentate patients with distal extension. MATERIALS AND METHODS: Twenty patients with two or more adjacent teeth missing in the distal extension and scheduled to receive implant-supported fixed prostheses were enrolled. Two interocclusal recording methods were used: placing polyvinyl siloxane (PVS) on the interocclusal recording caps (test), and placing PVS on healing abutments (control). The intraoral occlusal contacts in maximal intercuspal position (MIP) were compared with those in the mounted casts to calculate sensitivity and positive predictive value (PPV). Then, patients were randomly allocated into two groups to determine which interocclusal record would be used. The implant prostheses' evaluations mainly included occlusal adjustment height, volume, and time, occlusal contact score based on articulating paper examination. Paired-samples t-test, Mann-Whitney U test, and least squares regression analyzed the statistic differences. RESULTS: The test method had higher sensitivity to detect intraoral occlusal contacts than the control method (p = .002), but similar PPV (p = .10). During the prostheses' evaluations, the occlusal adjustment height in the test group was significantly lower than that in the control group [99.4 (53.2, 134.2) vs. 159.0 (82.3, 247.8) μm, p = .03], while the occlusal contact score before adjustment was higher (p = .006). The groups had similar occlusal adjustment volume and time. CONCLUSIONS: The novel interocclusal recording method for implant-supported fixed prostheses was more accurate and could reduce the occlusal adjustment.

来源:Clin Oral Implants Res,查看原文。版权归原作者所有。

引用

  1. Ding Q, Pu T, Tu Y, et al. Effect of a novel interocclusal recording method on occlusal accuracy of implant-supported fixed prostheses: A randomized clinical trial. Clin Oral Implants Res. 2023. PMID: 36695644. doi:10.1111/clr.14040

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。