牙槽嵴形态与导孔设计对静态计算机辅助种植手术精度的影响:体外研究
本体外研究评估牙槽嵴形态对静态计算机辅助种植手术(sCAIS)精度的影响,并次要评估导孔设计与种植体宏设计对最终种植体位置精度的影响。共使用18个标准化部分无牙上颌模型,植入72枚种植体。结果显示愈合牙槽嵴、无套筒导孔及深螺纹锥形种植体的偏差显著更低。
要点
- 愈合牙槽嵴种植体嵴顶、根尖及角度偏差均显著低于新鲜拔牙窝。
- 无套筒导孔设计较厂家套筒设计显著降低根尖及角度偏差。
- 深螺纹锥形骨水平种植体较浅螺纹平行壁种植体各维度偏差显著更低。
核心结论
- sCAIS最终种植体位置的精度由牙槽嵴形态、导孔设计及种植体宏设计共同决定。
研究设计与样本
- 体外研究,使用18个标准化部分无牙上颌模型,含两种牙槽嵴形态,共植入72枚种植体并均分至各研究组。
主要发现
- 愈合牙槽嵴组嵴顶偏差0.36 ± 0.17 mm、根尖偏差0.69 ± 0.36 mm、角度偏差1.86 ± 0.99°,均显著低于新鲜拔牙窝组的0.80 ± 0.29 mm、1.61 ± 0.59 mm、4.33 ± 1.87°(所有p<0.0001)。
- 无套筒导孔组根尖偏差1.02 ± 0.66 mm、角度偏差2.72 ± 1.93°,显著低于厂家套筒组的1.27 ± 0.67 mm(p=0.01)和3.46 ± 1.9°(p=0.02)。
- 深螺纹锥形骨水平种植体组嵴顶偏差0.49 ± 0.28 mm、根尖偏差0.97 ± 0.63 mm、角度偏差2.63 ± 1.85°,显著低于浅螺纹平行壁骨水平种植体组的0.67 ± 0.34 mm(p=0.0005)、1.32 ± 0.67 mm(p=0.003)、3.56 ± 1.93°(p=0.01)。
临床怎么用
- 作者指出,愈合牙槽嵴形态、深螺纹锥形种植体宏设计及无套筒手术导孔可获得更高的最终种植体位置精度。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The primary aim of this in vitro study was to evaluate the influence of alveolar ridge morphologies on the accuracy of static Computer-Assisted Implant Surgery (sCAIS). The secondary aims were to evaluate the influence of guide-hole design and implant macro-design on the accuracy of the final implant position. METHODS: Eighteen standardized partially edentulous maxillary models with two different types of alveolar ridge morphologies were used. Each model was scanned via cone beam computer tomography prior to implant placement and scanned with a laboratory scanner prior to and following implant placement using sCAIS. The postsurgical scans were superimposed on the initial treatment planning position to measure the deviations between planned and postsurgical implant positions. RESULTS: Seventy-two implants were equally distributed to the study groups. Implants placed in healed alveolar ridges showed significantly lower mean deviations at the crest (0.36 ± 0.17 mm), apex (0.69 ± 0.36 mm), and angular deviation (1.86 ± 0.99°), compared to implants placed in fresh extraction sites (0.80 ± 0.29 mm, 1.61 ± 0.59 mm, and 4.33 ± 1.87°; all p<0.0001). Implants placed with a sleeveless guide-hole design demonstrated significantly lower apical (1.02 ± 0.66 mm) and angular (2.72 ± 1.93°) deviations compared to those placed with manufacturer's sleeves (1.27 ± 0.67 mm; p = 0.01, and 3.46 ± 1.9°; p = 0.02). Deep-threaded tapered bone level implants exhibited significantly lower deviations at the crest (0.49 ± 0.28 mm), apex (0.97 ± 0.63 mm), and angular deviations (2.63 ± 1.85°) compared to shallow-threaded parallel-walled bone level implants (0.67 ± 0.34 mm; p = 0.0005, 1.32 ± 0.67 mm; p = 0.003, and 3.56 ± 1.93°; p = 0.01). CONCLUSIONS: The accuracy of the final implant position with sCAIS is determined by the morphology of the alveolar ridge, the design of the guide holes, and the macrodesign of the implant. CLINICAL SIGNIFICANCE: Higher accuracy in the final implant position was observed with implants placed in healed alveolar ridge morphologies, in implants with deep-threaded tapered macro-design, and when sleeveless surgical guide holes were used.
引用
- Dulla FA, Couso-Queiruga E, Chappuis V, et al. Influence of alveolar ridge morphology and guide-hole design on the accuracy of static Computer-Assisted Implant Surgery with two implant macro-designs: An in vitro study. J Dent. 2023. PMID: 36652971. doi:10.1016/j.jdent.2023.104426
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。