上颌融合磨牙牙本质厚度取决于融合类型:离体微型CT研究
本研究采用微型CT对120颗上颌融合磨牙进行扫描,测量根管周围牙本质厚度并按融合类型分组比较。结果显示无论融合类型如何,在根管口水平根尖向2 mm处牙本质厚度显著减小;第二近中颊根管周围最小牙本质厚度为0.30 mm(根管口下6 mm处)。近中颊根管牙本质厚度在融合类型1中显著大于类型2和3,而远中颊根管和腭根管牙本质厚度在类型3中显著薄于类型1或6。
要点
- 上颌融合磨牙根管口水平根尖向2 mm处牙本质厚度显著减小,与融合类型无关
- 第二近中颊根管周围最小牙本质厚度为0.30 mm,位于根管口下6 mm处
- 近中颊根管牙本质厚度融合类型1显著大于类型2和3
核心结论
- 上颌融合第二磨牙远中颊根管和腭根管危险区的最小牙本质厚度值随融合类型而变化。
研究设计与样本
- 离体微型CT研究,从拔除上颌磨牙库中选取120颗融合上颌磨牙,要求具有多个根管且在釉牙骨质界附近有 distinct 根管口。
- 使用微型CT设备(SkyScan 1172, Bruker-microCT)扫描,采用CTAn软件(v.1.18.8 Bruker-microCT)每隔1 mm测量根管周围根分叉方向最小牙本质厚度。
- 标本按融合类型分组,比较根管周围牙本质厚度,数据采用方差分析和post hoc Tukey-Kramer检验,先以Kolmogorov-Smirnov检验评估正态性(p < .05)。
主要发现
- 无论融合类型如何,在根管口水平根尖向2 mm处牙本质厚度显示统计学显著减小。
- 最小牙本质厚度值检测到位于第二近中颊根管周围,为根管口下6 mm处0.30 mm。
- 近中颊根管周围牙本质厚度在融合类型1中显著大于类型2和3(p < .05)。
- 远中颊根管和腭根管牙本质厚度在融合类型3中显著薄于类型1或6(p < .05)。
关键数值与推荐
- 最小牙本质厚度值:第二近中颊根管在根管口下6 mm处为0.30 mm。
- 近中颊根管牙本质厚度:融合类型1显著大于类型2和3(p < .05)。
- 远中颊根管和腭根管牙本质厚度:融合类型3显著薄于类型1或6(p < .05)。
临床怎么用
- 原文未据此给出临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: The present study aimed to determine and compare the dentine thickness around the root canals of maxillary molars with fusion using micro-computed tomography (micro-CT). METHODOLOGY: A total of 120 fused maxillary molars having more than a single canal with distinct canal orifices near the cementoenamel junction were selected from a pool of extracted maxillary molars, which were scanned on a micro-CT device (SkyScan 1172, Bruker-microCT). The minimum dentine thickness around the root canals in furcal direction was measured using CTAn software (v.1.18.8 Bruker-microCT) at each millimetre. The specimens were grouped according to their fusion type, and dentine thickness around the canals was compared. The data were statistically analysed using anova and post hoc Tukey-Kramer tests following an assessment of the normality of their distribution with the Kolmogorov-Smirnov test (p < .05). RESULTS: Dentine thickness showed a statistically significant decrease at 2 mm apical to the orifice level irrespective of fusion type. The minimum dentine thickness values were detected around the second mesiobuccal canal as 0.30 mm at 6 mm below orifice. Dentine thickness around the mesiobuccal canal was significantly greater in fusion type 1 than those of types 2 and 3 (p < .05), while those of distobuccal and palatal canals were significantly thinner in type 3 fusion compared with type 1 or 6 (pDentine thickness showed a statistically significant decrease at 2 mm apical to the orifice level irrespective of fusion type. The minimum dentine thickness values were detected around the second mesiobuccal canal as 0.30 mm at 6 mm below orifice. Dentine thickness around the mesiobuccal canal was significantly greater in fusion type 1 than those of types 2 and 3 ( CONCLUSION: Minimum dentine thickness values at the danger zone of distobuccal and palatal canals change according to the fusion type in fused maxillary second molars.
引用
- Keskin C, Toplu D, Keleş A, et al. Dentine thickness in maxillary fused molars depends on the fusion type: An ex vivo micro-computed tomography study. Int Endod J. 2023. PMID: 36637890. doi:10.1111/iej.13891
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。