模拟封闭与开放根管系统中冲洗液搅动装置的效果评估
本研究在环氧树脂模型中比较根尖封闭与开放(模拟根尖周病变)根管系统下冲洗液搅动装置的体外效果与安全性,共72个模型、每种系统分4组(n=9),使用1.3%次氯酸钠冲洗。结果显示开放系统对峡部清洁更有效,封闭系统中EDDY和超声搅动清洁最佳,开放系统中超声搅动单项最佳;EDDY对模拟根尖周病变明胶溶解最多,超声搅动最少。作者结论认为在本研究条件下,对已注入次氯酸钠冲洗液进行超声搅动比声波搅动方法更具侧向靶向性,因而更安全、更有效。
要点
- 封闭系统中EDDY和超声搅动对峡部清洁显著最佳(P<.05)。
- 开放系统中超声搅动对峡部清洁单项最佳(P<.05)。
- EDDY对模拟根尖周病变明胶溶解最多,超声搅动最少。
核心结论
- 在本研究条件下,对先前注入的次氯酸钠冲洗液进行超声搅动比声波搅动方法更具侧向靶向性,因而更安全、更有效。
研究设计与样本
- 体外研究,使用环氧树脂模型模拟根尖封闭与根尖开放(带模拟根尖周病变)根管系统,共72个模型。
- 每个模型含2条由峡部相连的根管,峡部填充牙本质碎屑,36个开放系统模型的模拟根尖周病变填充有色明胶。
- 每种系统分4个亚组(n=9):常规冲洗、声波低频(EndoActivator)、声波高频(EDDY)和超声搅动,均施加3个20秒循环。
- 冲洗液为1.3%次氯酸钠,比较峡部和模拟根尖周病变的总清除面积(mm²),使用参数检验(P<.05)。
主要发现
- 峡部清洁在根尖开放系统中比封闭系统更有效,且受搅动方法显著影响(P<.001)。
- 封闭系统中,EDDY和超声搅动对峡部清洁显著最佳(P<.05)。
- 开放系统中,超声搅动对峡部清洁显示单项最佳结果(P<.05)。
- EDDY对模拟根尖周病变中明胶的溶解远高于其他方法,超声搅动最低。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: The in vitro efficacy of irrigant activation devices has not been contrasted to their safety. This was attempted in this study using apically closed versus patent simulated root canal systems in epoxy resin models, with the latter featuring a simulated periapical lesion. METHODS: All 72 models had 2 joining canals connected by an isthmus, which was filled with dentin debris. The simulated periapical lesion was filled with colored gelatin in the 36 respective models. Canals were irrigated with 1.3% sodium hypochlorite. Samples were divided into 4 subgroups per system (n = 9): conventional irrigation, sonic low (EndoActivator; Dentsply Sirona, Charlotte, NC) and high frequency (EDDY; VDW, Munich, Germany), and ultrasonic agitation of the irrigant (always applying 3 cycles of 20 seconds). The total cleared surface areas (mm2) in the simulated isthmus and periapical lesion were compared between systems and devices using parametric tests (P < .05). RESULTS: The cleaning of the isthmus was more effective in the apically open compared with the closed systems and was also significantly influenced by the agitation method (P < .001). In the closed systems, EDDY and ultrasonic agitation achieved the significantly (P < .05) best cleaning of the isthmus. In the open systems, ultrasonic agitation showed the single best result (P < .05). EDDY caused by far the highest and ultrasonic agitation the lowest dissolution of the gelatin in the simulated periapical lesion. CONCLUSIONS: Under the conditions of this study, ultrasonic agitation of a previously administered sodium hypochlorite irrigant was more laterally targeted and thus safer and more effective than sonic agitation methods.
引用
- Al-Jadaa A, Saidi Z, Mahmoud M, et al. Assessment of Irrigant Agitation Devices in Simulated Closed and Open Root Canal Systems. J Endod. 2023. PMID: 36642215. doi:10.1016/j.joen.2023.01.002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。