仅用CBCT的简化导板开髓精度研究
本研究评估仅用术前锥形束CT(CBCT)的简化工作流程对离体下颌磨牙进行导板开髓的精度,并以CBCT联合三维口扫的工作流程作为参照。45颗下颌磨牙随机分为3组,结果显示各组偏差均较低且组间无显著差异,简化流程在有无冠部修复体时均获得高精度。
要点
- 仅用CBCT规划开髓在离体下颌磨牙中偏差低,与CBCT联合口扫流程结果相似。
- 有无冠部复合树脂修复体对简化流程的开髓精度无显著影响。
- 所有测试组在开髓预备后均可进入全部根管。
核心结论
- 仅使用CBCT检查的简化数字工作流程在离体磨牙(有或无冠部修复体)开髓中获得高精度,结果与CBCT联合三维口扫的工作流程相似。
研究设计与样本
- 将45颗离体下颌磨牙随机分为3组:对照组用CBCT与口扫进行数字化规划,实验1组仅用CBCT且牙无冠部修复体,实验2组仅用CBCT且牙有冠部复合树脂修复体。
- 开髓后再次CBCT扫描,重叠术前与术后检查,以毫米和角度计算规划与预备洞腔之间的偏差。
- 数据采用单因素方差分析比较(P < .05)。
主要发现
- 所有测试组在开髓预备后均可进入全部根管。
- 规划与预备开髓洞腔的偏差较低,对照组、实验1组和实验2组的平均偏差分别为0.55、0.58和0.47 mm,角度分别为1.98°、2.45°和1.43°。
- 3个测试组在毫米或角度偏差上均未观察到显著差异(P > .05)。
关键数值与推荐
- 对照组平均偏差0.55 mm、1.98°;实验1组平均偏差0.58 mm、2.45°;实验2组平均偏差0.47 mm、1.43°。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: This study evaluated the precision of a simplified workflow using only preoperative cone-beam computed tomographic (CBCT) scans to gain guided access to root canals of extracted mandibular molars. A workflow using CBCT scanning associated with 3-dimensional oral scanning was used as a reference for comparison. The influence of the presence of coronal restoration in the simplified workflow was also evaluated. METHODS: Forty-five mandibular molars were randomized into 3 groups: a control group in which digital planning was performed with CBCT and oral scanning and 2 experimental groups in which digital planning was performed only with CBCT examination. In experimental group 1, teeth had no coronal restorations, whereas in group 2 teeth presented with coronal composite restorations. After digital planning, the teeth were accessed using the guides, and a new CBCT scan was made to overlap the pre- and postoperative examinations. Precision was measured by calculating the deviation between the planned and prepared cavities in millimeters and angle. Data were compared using 1-way analysis of variance (P < .05). RESULTS: All root canals were accessible after access preparation in all tested groups. Deviations of the planned and prepared access cavities were low, with a mean value of 0.55, 0.58, and 0.47 mm and 1.98°, 2.45°, and 1.43° for the control group, group 1, and group 2, respectively. No significant differences in millimeters or angle were observed among the 3 tested groups (P > .05). CONCLUSIONS: The simplified digital workflow using only CBCT examination allowed a high level of precision in obtaining access in extracted molars with and without coronal restoration, presenting similar results compared with the digital workflow using CBCT and 3-dimensional oral scanning.
引用
- Chaves GS, Silva JA, Capeletti LR, et al. Guided Access Cavity Preparation Using a New Simplified Digital Workflow. J Endod. 2022. PMID: 36375649. doi:10.1016/j.joen.2022.11.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。