种植体相关特征对牙种植体晕影的影响:一项体外研究
该体外研究将60枚种植体以26种不同配置植入3D打印下颌骨,用两台锥形束CT(CBCT)设备评估种植体直径、覆盖螺丝、设计/材料、位置及额外种植体对种植体晕影的影响。两种CBCT设备均使种植体直径增大,钛种植体平均增加9.2%和11.8%,氧化锆种植体平均增加20.3%和24.4%(分别为ACC和NWT)。种植体直径增大并未增加晕影量,而放置覆盖螺丝则增加晕影量(ACC从8.0%增至10.9%,NWT从10.0%增至15.6%);种植体设计、解剖区域及另一枚种植体的存在也影响晕影程度。
要点
- 两种CBCT设备均使种植体直径增大,氧化锆种植体较钛种植体更明显。
- 种植体直径增大未增加晕影量,放置覆盖螺丝则增加晕影量。
- 种植体设计、解剖区域及额外种植体存在也影响晕影程度。
核心结论
- 牙种植体在CBCT上显示明显的直径增大,氧化锆种植体的效应较钛种植体更明显。
- 类似效应可能在临床环境中发生,可能掩盖骨结合失败、缩小种植体周围缺损尺寸和/或导致颊侧骨厚度被低估。
研究设计与样本
- 体外研究,将60枚种植体以26种不同配置植入3D打印下颌骨,使用两台CBCT设备(Accuitomo和NewTom)评估种植体晕影。
主要发现
- 两种CBCT设备均增大种植体直径:钛种植体平均增加9.2%(ACC)和11.8%(NWT),氧化锆种植体平均增加20.3%(ACC)和24.4%(NWT)。
- 种植体直径增大未增加晕影量,而放置覆盖螺丝增加晕影量:ACC从8.0%增至10.9%,NWT从10.0%增至15.6%。
- 种植体设计、解剖区域及另一枚种植体的存在也影响晕影程度。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: To assess, in vitro, variables potentially influencing implant blooming using a human-like imaging phantom and 3D-printed mandibles. MATERIAL AND METHODS: Sixty implants were inserted in 3D-printed mandibles in 26 different configurations in order to examine the impact of implant diameter, presence of a cover screw, implant design/material, implant position, and the presence of additional implants on implant blooming using two cone-beam computed tomography (CBCT) devices (Accuitomo [ACC] and NewTom [NWT]). Two observers measured the amount of implant blooming in both buccolingual and mesiodistal directions. Inter-rater agreement and descriptive statistics, grouped by implant characteristic and CBCT device, were calculated. RESULTS: Both CBCT devices increased implant diameter (a mean increase of 9.2% and 11.8% for titanium, 20.3% and 24.4% for zirconium, for ACC and NWT, respectively). An increase in implant diameter did not increase the amount of blooming, whereas placing a cover screw did (from 8.0% to 10.9% for ACC, and from 10.0% to 15.6% for NWT). Moreover, implant design, anatomical region, and the presence of another implant also affected the extent of the blooming. CONCLUSIONS: Dental implants show a clear diameter increase on CBCT, with the effect being more pronounced for zirconium than for titanium implants. Similar effects are likely to occur in the clinical setting, potentially masking nonosseointegration, reducing the dimensions of peri-implant defects, and/or causing underestimation of the buccal bone thickness.
引用
- Tarce M, de Greef A, Lahoud P, et al. The impact of implant-related characteristics on dental implant blooming: An in vitro study. Clin Oral Implants Res. 2022. PMID: 36189488. doi:10.1111/clr.14002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。