口外牙科吸引装置在牙髓开髓预备过程中消除气溶胶的临床疗效
本研究在8间闭门诊室中测量牙髓开髓预备时气溶胶量,比较使用与不使用口外牙科吸引装置(DTO)各20例,并在开髓后1分钟和15分钟记录。结果显示使用DTO联合高容量吸引在15分钟后气溶胶显著减少,但设备噪音对患者体验有负面影响。
要点
- 使用口外吸引装置联合高容量吸引在开髓后15分钟显著减少气溶胶。
- 开髓后1分钟,使用与不使用DTO的气溶胶均较高。
- 复合树脂和氧化锆在开髓后1分钟产生的气溶胶最多。
核心结论
- 口外吸引装置联合传统高容量吸引可增强气溶胶的减少。
- 使用该装置时噪音水平增加,可能对患者牙科体验产生负面影响。
研究设计与样本
- 在8间闭门住院医师诊室中,每晨操作前、操作中1分钟及开髓完成后15分钟测量气溶胶。
- 4间诊室放置CICADA DTO KN99口外牙科吸引装置(中国广东佛山蝉鸣),4间对照诊室不使用DTO。
- 完成使用DTO的20例和不使用DTO的20例,并分析数据。
主要发现
- 开髓后1分钟,使用与不使用DTO的气溶胶均较高。
- 使用DTO装置15分钟后,与仅用高容量吸引相比,气溶胶显著减少。
- 复合树脂和氧化锆在1分钟时产生的气溶胶最多。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: Coronavirus disease 2019 (COVID-19) has caused many concerns in the dental field regarding aerosol production and the transmission of the severe acute respiratory syndrome coronavirus 2 virus during dental procedures. Because of the abrupt arrival of COVID-19, there has been little to no published research on the efficacy of dental suction devices in the removal of aerosols related to COVID-19 or the impact extraoral suction devices have on patients' experiences. Therefore, the aim of this study was to measure the amount of aerosol produced during endodontic access preparation for root canal therapy with and without the use of an extraoral dental suction device and to gather information through a survey regarding patients' experiences. METHODS: Aerosol measurements were recorded in 8 closed-door resident operatories each morning before the procedures, 1 minute during the procedure, and 15 minutes after the access was complete. The CICADA DTO KN99 Extraoral Dental Suction Device (Foshan Cicada, Guangdong, China) was placed in 4 operatories, whereas no DTO extraoral suction device was used in 4 control operatories. Twenty cases with DTO and 20 cases without it were completed, and the data were analyzed. RESULTS: Aerosols 1 minute after access were higher with and without DTO. There was a significant reduction after 15 minutes when the DTO device was used compared to high-volume suction alone. Composite and zirconia produced the most aerosols at 1 minute. CONCLUSION: The results show that the reduction of aerosols is enhanced when the extraoral suction device is used in combination with traditional high-volume evacuation. However, the increased noise level when using the device can have a negative impact on patients' dental experience.
引用
- Barrett B, McGovern J, Catanzaro W, et al. Clinical Efficacy of an Extraoral Dental Evacuation Device in Aerosol Elimination During Endodontic Access Preparation. J Endod. 2022. PMID: 36206990. doi:10.1016/j.joen.2022.09.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。